Carrier Level Layered Modulation Method can Filter Out the Harmonics of Cascaded H - Bridge Topology

نویسنده

  • Wang Huadong
چکیده

Analysis of the reason of cascade H-bridge inverter topology using carrier phase shift modulation method cannot compensate the harmonic, using carrier level layered modulation method can solve the problem of cascade H-bridge topology that it cannot compensate harmonic problems. Experimental results show that the modulation algorithm can effectively reduce the modulation delay, improve the control bandwidth, it can also make the harmonic compensation capacity increase from 5 times to 21. The scope of the application of STATCOM is greatly increased in the grid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Harmonics Elimination Technique in Cascaded H-Bridge Multi-Level Inverters Using the Salp Swarm Optimization Algorithm

A new optimization method is proposed in this paper for finding the firing angles in multi-level voltage source inverters to eliminate low-order selective harmonics and reduce total harmonic distortion (THD) value of the output voltage. For thid end, Fourier series is used for calculating objective function and selecting specific harmonics. Regarding the nature and complexity of the employed no...

متن کامل

Comparison of Multicarrier PWM Techniques for Cascaded H-Bridge Multilevel Inverter

Received Jan 14, 2017 Revised Mar 14, 2017 Accepted Mar 29, 2017 One of the preferred choices of electronic power conversion for high power applications are multilevel inverters topologies finding increased attention in industry. Cascaded H-Bridge multilevel inverter is one of these topologies reaching the higher output voltage, power level and higher reliability due to its modular topology. Le...

متن کامل

A Novel Controller Based on Single-Phase Instantaneous p-q Power Theory for a Cascaded PWM Transformer-less STATCOM for Voltage Regulation

In this paper, dynamic performance of a transformerless cascaded PWM static synchronous shunt compensator (STATCOM) based on a novel control scheme is investigated for bus voltage regulation in a 6.6kV distribution system. The transformerless STATCOM consists of a thirteen-level cascaded H-bridge inverter, in which each voltage source H-bridge inverter should be equipped with a floating and iso...

متن کامل

Conduction and Dead-Time Voltage Drops Estimation of Asymmetric Cascaded H-Bridge Converters Utilizing Level-Shifted PWM Scheme

Linear AC power supplies can be replaced by their nonlinear switching counterparts due to the lower voltage drops and higher efficiency and power density of switching-mode inverters. Multilevel cascaded H-bridge (CHB) converters are the preferred inverter structure because of modular configuration, control, and protection. The output voltage quality in CHB converters depends on the number of ou...

متن کامل

THD Analysis of a 13 Level Asymmetric Hybrid Cascaded Multilevel Inverter for Industrial Applications

This paper proposes asymmetric cascaded H-bridge multilevel inverter with reduced number of switches suitable for industrial applications and renewable energy too. Cascade Multilevel Inverters are very popular and have many applications in electric utility and for industrial drives. When these inverters are used for industrial drive directly, the THD contents in output voltage of inverters are ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016