Redundancy reduction for improved display and analysis of body surface potential maps. II. Temporal compression.

نویسندگان

  • A K Evans
  • R L Lux
  • M J Burgess
  • R F Wyatt
  • J A Abildskov
چکیده

This paper describes use of the Karhunen-Loeve expansion to identify and reduce temporal redundancy in electrocardiographic body surface potential maps (192 body surface leads recorded simultaneously at 1 kHz/channel for approximately 600 msec). Temporal data compression of about 20 to 1 was obtained with accurate representation of the original data. Use of separate sets of orthonormal basis functions for QRS and ST-T provided a more accurate representation than the basis derived from QRST. Combined with the spatial compression described in the preceding paper, overall map data compression of about 320 to 1 was obtained without significant loss of accuracy of representation or map appearance. With both spatial and temporal compression the 100,000 numbers which typically comprise a single cardiac complex were accurately represented by 216 coefficients. Using basis functions derived from a single cardiac complex were accurately represented by 216 coefficients. Using basis functions derived from a training set of 221 maps, the estimated average rms error of representation was 60 microV during the ST-T. For 34 test maps which were not part of the training set, measured average errors were 64 microV during the QRS and 23 microV during the ST-T. This technique provides a basis for quantification of the diagnostic content of maps and automated classification of maps.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Redundancy reduction for improved display and analysis of body surface potential maps. I. Spatial compression.

The Karhunen-Loeve technique of random process representation was investigated as a method of quantitatively characterizing body surface potential maps. One hundred ninety-two lead body surface potential maps from 124 normal subjects and 97 patients with independently documented heart disease were used in the study. Each map frame in QRS and ST-T of 34 maps in a test set was represented as a li...

متن کامل

Redundancy Reduction for Improved Display and Analysis of Body Surface Potential Maps

The Karhunen-Loeve technique of random process representation was investigated as a method of quantitatively characterizing body surface potential maps. One hundred ninety-two lead body surface potential maps from 124 normal subjects and 97 patients with independently documented heart disease were used in the study. Each map frame in QRS and ST-T of 34 maps in a test set was represented as a li...

متن کامل

Spatio-temporal analysis of the covid-19 impacts on the using Chicago urban shared bicycles by tensor-based approach

 Cycling is a phenomenon in urban transportation that has the ability to allocate a specific location at any moment in time. Accordingly, spatial analysis of bicycle trips can be accompanied by temporal analysis. The use of a GIS environment is commonly recommended to display the extent of the phenomenon's spatial changes. However, in order to apply and display changes over time, it will requir...

متن کامل

Determining the Proper compression Algorithm for Biomedical Signals and Design of an Optimum Graphic System to Display Them (TECHNICAL NOTES)

In this paper the need for employing a data reduction algorithm in using digital graphic systems to display biomedical signals is firstly addressed and then, some such algorithms are compared from different points of view (such as complexity, real time feasibility, etc.). Subsequently, it is concluded that Turning Point algorithm can be a suitable one for real time implementation on a microproc...

متن کامل

Set a bi-objective redundancy allocation model to optimize the reliability and cost of the Series-parallel systems using NSGA II ‎problem‎

With the huge global and wide range of attention placed upon quality, promoting and optimize the reliability of the products during the design process has turned out to be a high priority. In this study, the researcher have adopted one of the existing models in the reliability science and propose a bi-objective model for redundancy allocation in the series-parallel systems in accordance with th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 49 1  شماره 

صفحات  -

تاریخ انتشار 1981