Comparative Evaluation of Advanced Coal-Based Power Plants

نویسنده

  • Yanzi Chen
چکیده

The purpose of this study is to comparatively evaluate four types of advanced conceptual power plants based on coal. With efficiency, costof-electricity, and emissions as main criteria, the evaluation was made under consistent design conditions and economic assumptions. The plants considered are a supercritical steam power plant (SC 580◦C), an indirectly coal-fired power system (HIPPS), an advanced pressurized fluidized-bed combustion power plant (PFBC), and an integrated gasification-combined-cycle power plant (IGCC). Reflecting the technology standard of the current coal power plants, a conventional steam power plant (PCC) was chosen for comparison. Exergetic and economic analyses have been performed for each type of the plants, together with parametric studies. The main sources of thermodynamic inefficiencies as well as the dominating contributors to the cost of electricity are identified. Potential improvements of both the performance and the cost effectiveness are discussed, and the environmental impact of each plant is briefly presented. The HIPPS appears to be the thermodynamically and economically most viable option, capable of achieving a 48.5% overall exergetic efficiency while allowing a levelized cost of electricity (LCE) by merely 3.7% higher than that of the PCC power plant. If the HIPPS is fueled only with coal, the system efficiency is expected to decrease by 3.7% and the LCE remains basically unchanged. The PFBC has the second highest plant efficiency, 5.8% lower than that of the HIPPS, and the lowest LCE among the four. The IGCC power plant possesses an exergetic efficiency 11.0% lower than that of the HIPPS and the highest LCE. The SC 580◦C yields the lowest overall exergetic efficiency among all the plants, 19.3% lower than that of the HIPPS. Still, it is 9.4% higher than that of the conventional PCC plant. The LCE of this plant lies between that of the HIPPS and that of the IGCC. Further elevating the steam parameters to 700◦C and 365 bar promises an increase of 7.5% in efficiency, without a necessary rise in the LCE. As a conclusion, among the four technologies, the HIPPS is the best option for the power generation based on coal in the far future. While SC power plants can be the choice to meet the short-term needs of new capacity, PFBC and IGCC plants could provide solutions for both middle-term power generation and use of low-rank fuel feedstock.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Markov Model for Performance Evaluation of Coal Handling Unit of a Thermal Power Plant

The present paper discusses the development of a Markov model for performance evaluation of coal handling unit of a thermal power plant using probabilistic approach. Coal handling unit ensures proper supply of coal for sound functioning of thermal Power Plant. In present paper, the coal handling unit consists of two subsystems with two possible states i.e. working and failed. Failure and repair...

متن کامل

Probabilistic Performance, Environmental, and Economic Evaluation of an Advanced Coal Gasification System

INTRODUCTION The acid rain provisions of the 1990 Clean Air Act Amendments (CAAA) provide new incentives for the development of power generation technology with low SO 2 emissions. Detailed evaluations of possible NO x and air toxics emission limits also are required by the CAAA in the next few years. Furthermore, reauthorization of other key environmental legislation, such as the Clean Water A...

متن کامل

The Study of Selection of Coal-Fired Supplier in Thermal Power Enterprise Based on the Extension Analysis Method

Abstract Electric power market competition is intense. The competition between the various power plants will is the contest of economic efficiency as the core. Fuel cost is the center link of production management and economic accounting in thermal power plant, so selection management of the coal-fired supplier has great significance for the development of thermal power enterprise and improveme...

متن کامل

Radon monitoring in gas turbine and thermal power station A comparative study

Background: In this study, measurement of indoor radon and its progeny levels was carried out in Gas Turbine Power Station in Haryana ( India ), where natural gas is used as fuel. For comparison, the results of a study carried out in thermal power plant in Haryana are also presented. Radon being a ubiquitous air pollutant has global impact and its monitoring in the environment at work places is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001