Comparability of three output prediction models for a compact passively double‐scattered proton therapy system

نویسندگان

  • Sven Ferguson
  • Yong Chen
  • Clara Ferreira
  • Mohammad Islam
  • Vance P Keeling
  • Andy Lau
  • Salahuddin Ahmad
  • Hosang Jin
چکیده

The purpose of this study was to investigate comparability of three output prediction models for a compact double-scattered proton therapy system. Two published output prediction models are commissioned for our Mevion S250 proton therapy system. Model A is a correction-based model (Sahoo et al., Med Phys, 2008;35(11):5088-5097) and model B is an analytical model which employs a function of r = (R'-M')/M' (Kooy et al., Phys Med Biol, 2005;50:5487-5456) where R' is defined as depth of distal 100% dose with straggling and M' is the width between distal 100% dose and proximal 100% dose with straggling instead of the theoretical definition due to more accurate output prediction. The r is converted to ((R-0.31)-0.81 × M)/(0.81 × M) with the vendor definition of R (distal 90% dose) and M (distal 90% dose-to-proximal 95% dose), where R' = R-0.31 (g cm-2 ) and M' = 0.81 × M (g cm-2 ). In addition, a quartic polynomial fit model (model C) mathematically converted from model B is studied. The outputs of 272 sets of R and M covering the 24 double scattering options are measured. Each model's predicted output is compared to the measured output. For the total dataset, the percent difference between predicted (P) and measured (M) outputs ((P-M)/M × 100%) were within ±3% using the three different models. The average differences (±standard deviation) were -0.13 ± 0.94%, -0.13 ± 1.20%, and -0.22 ± 1.11% for models A, B, and C, respectively. The p-values of the t-test were 0.912 (model A vs. B), 0.061 (model A vs. C), and 0.136 (model B vs. C). For all the options, all three models have clinically acceptable predictions. The differences between models A, B, and C are statistically insignificant; however, model A generally has the potential to more accurately predict the output if a larger dataset for commissioning is used. It is concluded that the models can be comparably used for the compact proton therapy system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proton Therapy of eye using MCNPX code

Introduction: Proton radiotherapy is the one of advanced teletherapy methods. The protons deposit their maximum energy in a position called Bragg peak. Therefore, for treatment of cancer, the tumor should be placed at the Bragg peak or SOBP. The scattered photons and neutrons is a challenge in proton radiotherapy. The aim of this study is calculation of absorbed dose from scatt...

متن کامل

Development of a Scanning System for Proton Therapy in Uppsala

A scanned proton beam yields dose distributions that in most cases are superior to other external radiation treatment modalities, and also to passively scattered proton beams. The present paper gives a description of the scanning system that has been developed at the The Svedberg Laboratory (TSL) in Uppsala. The solution with a small polegap of the magnets and a moveable second magnet gives a v...

متن کامل

Calculation of Neutron Dose Ratio of Heart, Lung and Liver due to breast cancer Proton Therapy using MCNPX code

Introduction: The proton beam produced in particle accelerators has an appropriate therapeutic potential. In this research, proton therapy of breast cancer is simulated using the MCNPX code in a MIRD phantom, also the contribution of scattered neutron dose during the proton therapy were calculated for the Heart, Lung and Liver.   Materials and Methods: For si...

متن کامل

Multi-Output Adaptive Neuro-Fuzzy Inference System for Prediction of Dissolved Metal Levels in Acid Rock Drainage: a Case Study

Pyrite oxidation, Acid Rock Drainage (ARD) generation, and associated release and transport of toxic metals are a major environmental concern for the mining industry. Estimation of the metal loading in ARD is a major task in developing an appropriate remediation strategy. In this study, an expert system, the Multi-Output Adaptive Neuro-Fuzzy Inference System (MANFIS), was used for estimation of...

متن کامل

The risk of developing a second cancer after receiving craniospinal proton irradiation.

The purpose of this work was to compare the risk of developing a second cancer after craniospinal irradiation using photon versus proton radiotherapy by means of simulation studies designed to account for the effects of neutron exposures. Craniospinal irradiation of a male phantom was calculated for passively-scattered and scanned-beam proton treatment units. Organ doses were estimated from tre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017