Partial Discharge Detection in Solid Dielectrics

نویسنده

  • P. Sreejaya
چکیده

Partial Discharge (PD) measurement and characterization provide vital information on insulation condition, different aspects of insulation ageing useful for equipment integrity verification and diagnosis. The work demonstrates standard test methods which employs capture of PD parameters with the aid of discharge detector. This paper investigates on the voltage amplitude at which PD of a specified magnitude commence and determines the apparent charge, discharge energy and power dissipation for discharge quantity at a specified voltage. PD detection and measurement procedures suitable for use on Current Transformers, Insulators and Air Break (AB) switches are examined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Field Electrical Conduction and Breakdown in Solid Dielectrics: A Signal Denoising Techniques by Wavelet Transform

One of the most important challenges of on-site partial discharge measurement is to capture the original signal in a noisy environment. The different sources of noise which includes thermal or resister noise added by the measuring circuit, signals due to electromagnetic interferences. Sophisticated and proper methods are required to detect and measured the partial discharge signals. Fortunately...

متن کامل

EFFECT OF ELECTRIC FIELD ON PD ACTIVITY AND DAMAGE INTO SOLID DIELECTRIC MATERIALS

Abstract – In this paper, the effect of applied electric field on the damage due to partial discharges activity into the surroundings dielectrics of a narrow channel encapsulated within the volume of a dielectric material is evaluated using a kinetic model based on Particle in Cell - Monte Carlo Collision (PIC-MCC) model. After application of an electric field across a dielectric material which...

متن کامل

Analysis and Diagnosis of Partial Discharge of Power Capacitors Using Extension Neural Network Algorithm and Synchronous Detection Based Chaos Theory

Power capacitors are important equipment of the power systems that are being operated in high voltage levels at high temperatures for long periods. As time goes on, their insulation fracture rate increases, and partial discharge is the most important cause of their fracture. Therefore, fast and accurate methods have great importance to accurately diagnosis the partial discharge. Conventional me...

متن کامل

A Novel Partial Discharge Calibrator Design via Dual Microconroller and High Speed Dac

Insulation is a crucial phenomenon for high voltage apparatus. Partial discharge activity affects the service life of the dielectrics. Therefore partial discharge must be less than a specified value for high voltage equipment. An accurate partial discharge measurement strongly depends on scaling of the measurement systems. It is a general method to use a partial discharge calibrator to calibrat...

متن کامل

On the electrodynamics of partial discharges in voids in solid dielectrics

Until1 now paper 3-phase belt type cables were succesfully used for voltages upto 20 kV in great parts of the world. Replacement of paper by extruded insulation has been unsuccesfull and service voltages no higher than 5 kV can be applied because of the large discharges and uncontrolled field in the interstices at the core and the belt. Belt-type cables remained paper-insulated for that reason....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013