Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.

نویسندگان

  • H Dittrich
  • P Nicod
  • B Hoit
  • N Dalton
  • D Sahn
چکیده

We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 patients with normally functioning mitral valves, the ratios of the maximal major and minor Doppler-imaged orifice flow diameters to the valve ring diameters were 25 +/- 3% (mean +/- SD) and 24 +/- 3%, respectively, similar to values reported in in vitro studies. No mitral regurgitation was found in these patients by two-dimensional Doppler echocardiographic flow mapping or by spectral Doppler. Of the 10 clinically normal aortic Björk-Shiley valves, no valvular regurgitation was found by color flow mapping, whereas mild aortic regurgitation was found in two patients with the use of spectral Doppler. Malfunction of six valves was documented in five patients and was confirmed by cardiac catheterization and/or surgery. These included one case of focal fibrous ingrowth involving primarily the minor orifice of a mitral prosthetic valve, one case of mitral valve prosthetic thrombosis with decreased major and minor orifice flow diameters and valvular regurgitation, and four cases of paravalvular regurgitation involving prosthetic valves in the aortic position (three patients) and the mitral position (one patient). Two-dimensional Doppler echocardiographic flow mapping provides new observations that may aid in identifying Björk-Shiley prosthetic valve malfunction. By localizing precisely the site of prosthetic stenosis or regurgitation, it may also assist in defining the cause of valve malfunction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler echocardiographic characteristics of normal and dysfunctioning prosthetic valves in the tricuspid and mitral position.

The Doppler echocardiographic characteristics of 70 prosthetic valves in 35 patients are reported. Twenty nine patients had a Björk-Shiley prosthesis in both mitral and tricuspid positions and six had Carpentier-Edwards valves in both sites. Five of the patients had abnormal tricuspid prostheses on the basis of clinical and echocardiographic criteria. Pulsed wave Doppler echocardiography was us...

متن کامل

Doppler and two-dimensional echocardiographic diagnosis of Björk-Shiley prosthetic valve malfunction: importance of interventricular septal motion and the timing of onset of valve flow.

In a 69 year old woman with a "sticking" Björk-Shiley mitral prosthesis, the diagnosis was suggested by both the two-dimensional and the Doppler ultrasound examinations. In particular, the findings of early diastolic paradoxic septal motion, intermittent delayed opening of the prosthetic disc and variable timing of the onset of mitral valve inflow were believed to be diagnostic of a sticking ti...

متن کامل

Validation of continuous-wave Doppler echocardiographic measurements of mitral and tricuspid prosthetic valve gradients: a simultaneous Doppler-catheter study.

For patients with stenotic native valves, the modified Bernoulli equation (delta P = 4V2) may be applied to Doppler-measured transvalvular velocities to yield an accurate estimate of transvalvular gradients. Although it would be useful if the same approach could be used for those with stenotic prosthetic valves, no previous study has validated the Doppler technique in this setting. We therefore...

متن کامل

Two-dimensional echocardiographic features of Björk-Shiley aortic prosthetic valve dehiscence.

Dehiscence of the valve is a serious complication of prosthetic heart valve replacement. It has grave consequences unless promptly diagnosed and corrected by surgery. We report the case of a symptomless patient with near-complete detachment of the aortic prosthesis, diagnosed by radiography and two-dimensional echocardiography. This was confirmed at surgery and the dehisced prosthetic valve was...

متن کامل

Prevalence and characteristics of intracranial microemboli signals in patients with different types of prosthetic cardiac valves.

BACKGROUND AND PURPOSE Transcranial Doppler detection of microemboli is widely described, but there is no clear evidence of the clinical significance or nature of the embolic material in vivo. Thromboembolism is a major cause of morbidity in patients with prosthetic cardiac valves. We undertook this study to evaluate the prevalence and the acoustic characteristics of microembolic signals in thr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 71 5  شماره 

صفحات  -

تاریخ انتشار 1985