Incidence, predictors and outcomes of hematoma after ICD implantation: An analysis of a nationwide database of 85,276 patients

نویسندگان

  • Arun Raghav Mahankali Sridhar
  • Vivek Yarlagadda
  • Arun Kanmanthareddy
  • Sravanthi Parasa
  • Ryan Maybrook
  • Buddhadeb Dawn
  • Yeruva Madhu Reddy
  • Dhanunjaya Lakkireddy
چکیده

BACKGROUND Pocket hematoma is one of the most common complications following cardiac device implantation. This study examined the impact of this complication on in-hospital outcomes following Implantable Cardioverter Defibrillator (ICD) implantation. METHODS Data from Nationwide Inpatient Sample (NIS) 2010 was queried to identify all primary implantations of ICDs and Cardiac Resynchronization Therapy Defibrillators (CRT-D) during the year 2010 using ICD-9 codes. We then identified the patients who experienced a procedure related hematoma during the hospital stay. We compared the outcomes of the patients with and without a hematoma complication. All analyses were performed using SPSS 20 complex samples using appropriate weights to adjust for the complex sampling design of the national database. RESULTS Out of a total of 85,276 primary ICD implantations in the year 2010, 2233 (2.6% of the implantations) were complicated by a hematoma. Increased age (p < 0.001), and comorbidities such as congestive heart failure (odds ratio (OR) - 1.86, p < 0.001), coagulopathy (OR - 2.3, p < 0.001) and renal failure (OR - 1.52, p < 0.001) were associated with an increased risk of pocket hematoma formation. Patients who developed a hematoma had a longer hospitalization (9.1 days versus 5.5 days, p < 0.001) and higher in-hospital costs ($56,545 versus $47,015, p < 0.001) compared to patients who did not have a hematoma. Overall mortality associated with ICD implantation was low (0.6%), and hematoma formation did not adversely affect mortality (0.6% versus 0.4%, p = 0.63). CONCLUSION Hematoma occurs infrequently after ICD implantation, however, it adversely impacts the cost of procedure and length of stay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk of hematoma complications after device implant in the clopidogrel era.

BACKGROUND Device implant pocket hematoma is a recognized complication after permanent pacemaker (PM) and implantable cardioverter-defibrillator (ICD) implantation. Pocket hematoma is associated with local discomfort, an increased risk of infection, and may require surgical intervention or lead to lengthier hospital stays. The purpose of the study was to identify the clinical factors associated...

متن کامل

Identifying the predictors of hematoma after device implantation: Closing in on the suspects with an aim to prevent the menace?

Implantation of various cardiac implantable electronic devices (CIED) is becoming increasingly common day by day. At the same time, the recipient patient population, especially that of implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy (CRT-P and CRT-D) devices, is also getting older with greater co-morbidities, including atrial fibrillation. As a result, various ...

متن کامل

بررسی اثر مداخلات شناختی- رفتاری بر سلامت روان بیماران با دفیبریلاتور داخل قلبی

Background: Several studies that have evaluated psychological and counseling interventions suggest that a proactive approach may be effective in preparing patients for the experience of living with an implantable cardioverter-defibrillator (ICD). The purpose of this study was to develop and assess cognitive and behavioral interventions in reducing stress and anxiety and improving quality of lif...

متن کامل

Complications in recipients of cardioverter-defibrillator or cardiac resynchronization therapy: Insights from Silesian Center Defibrillator registry.

BACKGROUND Current real-life information from all-comers registries from middle and east Europe about the incidence and type of complications during long-term follow-up of patients with cardioverters-defibrillators (ICD) and cardiac resynchronization devices-defibrillators (CRT-D) is still insufficient. The aim of the study was to assess the incidence and determinants of short- and long-term co...

متن کامل

In-Hospital Outcomes after Hemiarthroplasty versus Total Hip Arthroplasty for Isolated Femoral Neck Fractures

  Background:    Previous studies suggest total hip arthroplasty may have some benefits compared to hemi-arthroplasty for displaced intracapsular femoral neck fractures in patients more than 60 years of age. The primary research question of our study was whether in-hospital adverse events, post-operative length of stay (LOS) and mortality in patients 60 year of age or older differed between tot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016