Evaluation of a rapid analyte measurement platform and real-time reverse-transcriptase polymerase chain reaction assay West Nile virus detection system in mosquito pools.

نویسندگان

  • Kristen L Burkhalter
  • Kalanthe Horiuchi
  • Brad J Biggerstaff
  • Harry M Savage
  • Roger S Nasci
چکیده

We evaluated the commercially available Rapid Analyte Measurement Platform (RAMP) West Nile virus (WNV) antigen detection test for sensitivity and consistency with real-time reverse transcriptase polymerase chain reaction (RT-PCR) confirmation testing. Panels of samples consisting of WNV-spiked mosquito pools and negative control pools were sent to 20 mosquito abatement districts (MADs) that processed the pools using the RAMP assay. The samples were then sent to the reference laboratories used by the MADs for confirmation by real-time RT-PCR. Positive pools with virus titers of roughly 1-3 log10 PFU/ml had RAMP scores above the RAMP test positive cutoff score of 30 RAMP units, but these virus-positive samples could not be reliably confirmed by real-time RT-PCR testing. Pools with virus titers > or =4 log10 PFU/ml scored > or =50 RAMP units. Real-time RT-PCR results varied among the confirmation laboratories. With few exceptions, pools returning a RAMP score of > or =100 were confirmed with real-time RT-PCR, while pools returning a RAMP score of 50-99 appeared to be at the limit of real-time RT-PCR detection. Therefore, we recommend using a positive cutoff of 50 RAMP units with no real-time RT-PCR confirmation to maximize speed, efficiency, and economy of the RAMP assay. A more conservative approach would be to implement a "gray zone" range of 50-100 RAMP units. Pools scoring within the gray zone could be submitted for real-time RT-PCR confirmation with the understanding that positive pools may not confirm due to the inhibitory effect of the RAMP buffer on the real-time RT-PCR assay. We also conducted a series of experiments using laboratory-prepared mosquito pools spiked with WNV to compare mosquito homogenization buffers, pool sizes, and grinding methods in order to determine how these variables affect the RAMP and real-time RT-PCR assay results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiplex qRT-PCR for the Detection of Western Equine Encephalomyelitis, St. Louis Encephalitis, and West Nile Viral RNA in Mosquito Pools (Diptera: Culicidae).

Following the introduction of West Nile virus into California during the summer of 2003, public health and vector control programs expanded surveillance efforts and were in need of diagnostics capable of rapid, sensitive, and specific detection of arbovirus infections of mosquitoes to inform decision support for intervention. Development of a multiplex TaqMan or real-time semiquantitative rever...

متن کامل

Comparative field analyses of rapid analyte measurement platform and reverse transcriptase polymerase chain reaction assays for West Nile virus surveillance.

Rapid detection of West Nile virus (WNV) in mosquito pools is essential for predicting epizootics and epidemics. We compare the efficiency and sensitivity of the Rapid Analyte Measurement Platform (RAMP) to reverse transcriptase polymerase chain reaction (RT-PCR) from 2005 to 2008 from field mosquito populations in Mercer County, NJ. Overall, 316 pools tested negative and 115 pools tested posit...

متن کامل

Evaluation of a rapid analyte measurement platform for West Nile virus detection based on United States mosquito control programs.

The rapid analyte measurement platform (RAMP) system is an immunoassay test for West Nile virus (WNV) detection. Although reverse transcriptase-polymerase chain reaction (RT-PCR) methodology has been regarded as the gold standard for confirming WNV presence, usage of RAMP testing kits has increased in the past years. We collected RAMP test result data that were subsequently confirmed with RT-PC...

متن کامل

Assays to Detect West Nile Virus in Dead Birds

Using oral swab samples to detect West Nile virus in dead birds, we compared the Rapid Analyte Measurement Platform (RAMP) assay with VecTest and real-time reverse-transcriptase-polymerase chain reaction. The sensitivities of RAMP and VecTest for testing corvid species were 91.0% and 82.1%, respectively.

متن کامل

Evaluation of commercial assays for detecting West Nile virus antigen.

Two commercially available West Nile virus (WNV) detection assays (RAMP WNV test, Response Biomedical Corp., Burnaby, British Columbia, Canada; and VecTest WNV antigen assay, Medical Analysis Systems, Inc., Camarillo, CA) were compared for sensitivity, specificity, and ability to detect WNV in field-collected mosquito pools. Serially diluted stock seed WNV and St. Louis encephalitis virus (SLEV...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Mosquito Control Association

دوره 30 1  شماره 

صفحات  -