Multiparameter Monitoring and Fault Indication Using Inductive Power Transfer System
نویسندگان
چکیده
— The paper aims at demonstrating communication capabilities of IPT. For this data communication is performed between two modules using the concept of IPT. IPT was deemed to be the best solution to the system houses a multi parameter acquisition module such as temperature, speed, voltage, current and data transfer from the motor. The receiver side is another microcontroller coupled to an inductive coil that gets the data and displays in the LCD. A brief background to IPT (Inductive Power Transfer) technology and its applications is given and the design criteria for the paper are defined in detail. To be accurate, IPT data communication helps to reduce unnecessary wire connections and data is transmitted without any touch. Further the paper can be enhanced by looking for fault analysis inside the motor. This can be done by analyzing various parameters of the motor. A novel two-way IPT communication system was designed, which worked on the concept of pulsing the system on and off to send data serially. The paper involves transmission of data through inductive flux without any contact between the two modules. Further as no frequency tunings or any calibration is required between different modules a single system can be used with multiple clients. This reduces a lot of hazards such as interference with other modules and RF transmitters in the vicinity.
منابع مشابه
Selection of Resistive and Inductive Superconductor Fault Current Limiters Location Considering System Transient Stability
Superconductor fault current limiter (SFCL) is an effective device to suppress high fault currents. This paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. Appropriate location and type of the limiters in a HV substation is selected by a qualitative approach based on the equal area criterion. Study system is simulated by...
متن کاملA New System of Contactless Power Transfer with Low Voltage Stress and Parasitic Capacitors Effect
In this paper, a high frequency contactless power transfer (CPT) system is designed with ∅2 inverter drive. This system works in 30MHz frequency and 380W power with low voltage stress and considers the inductive link parasitic capacitor effect. In the design, we formulated the inverter equations first and then suggested another design for the transmitter and the receiver coils as the energy tra...
متن کاملInfluence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملImplementation of Identical Spiral Square Inductive Coils for Wireless EV Battery Charging Application
In recent years, the popularity of wireless inductive power transfer (WIPT) system for electric vehicle battery charging (EVBC) is always ever-increasing. In the WIPT inductively coupled coil structure is the heart of the system and the mutual inductance (MI) between the coupled coils is the key factor for effective power transfer. This paper presents the analysis of mutual inductance between t...
متن کاملCable Fault Monitoring and Indication: A Review
Underground cable power transmission and distribution system are susceptible to faults. Accurate fault location for transmission lines is of vital importance. A quick detection and analysis of faults is necessity of power retailers and distributors. This paper reviews various fault locating methods and highly computational methods proposed by research community that are currently in use. The pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- CoRR
دوره abs/1309.0589 شماره
صفحات -
تاریخ انتشار 2013