Wide two-dimensional field laser ray-tracing aberrometer.
نویسندگان
چکیده
There is an increasing interest in measuring the peripheral optical quality of the eye. Optical aberrations have been studied extensively in the center of the visual field due to the development of Hartmann-Shack wavefront sensor. However, experimental data of the peripheral field of view are still scarce, partly due to the fact that this evaluation presents various challenges. Here, we propose a novel device based on the laser ray-tracing (LRT) aberrometer, which is well suited for measuring the off-axis aberrations. The proposed instrument is able to measure a wide (±40°) 2D visual field and is based on three main design principles: spiral-shaped sampling of the visual field, real-time detection of the eye's entrance pupil, and automatic shaping and delivering of the ray bundle that optimally samples the eye pupil. We present experimental data obtained on 11 healthy subjects and a novel analysis based on a 2D quadratic model of the aberrations as a function of visual field and azimuth. The obtained results are consistent with previous findings.
منابع مشابه
An Efficient Algorithm for General 3D-Seismic Body Waves (SSP and VSP Applications)
Abstract The ray series method may be generalized using a ray centered coordinate system for general 3D-heterogeneous media. This method is useful for Amplitude Versus Offset (AVO) seismic modeling, seismic analysis, interpretational purposes, and comparison with seismic field observations.For each central ray (constant ray parameter), the kinematic (the eikonal) and dynamic ray tracing system ...
متن کاملThe absorption of light by rough metal surfaces—A three-dimensional ray-tracing analysis
The laser absorptance of rough surfaces has been investigated by using Monte Carlo simulations based on three-dimensional 3D ray tracing. The influence of multiple scattering, shadowing, and the Fresnel-equation based angle dependence is discussed. The 3D results are compared to previously published results from a two-dimensional ray-tracing analysis and the different applications of the two mo...
متن کاملReconstruction of the optical system of the human eye with reverse ray-tracing.
We present a practical method for reconstructing the optical system of the human eye from off-axis wavefront measurements. A retinal beacon formed at different locations on the retina allows probing the optical structure of the eye by the outgoing beams that exit the eye through the dilated pupil. A Shack-Hartmann aberrometer measures the amount of wave aberrations in each beam at the exit pupi...
متن کاملEvaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes
PURPOSE We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter i...
متن کاملTwo-dimensional near-field and far-field imaging of a Ne-like Ar capillary discharge table-top soft-x-ray laser
We have performed systematic measurements and numerical modeling of the divergence and exit beam size of a 46.9 nm Ne-like Ar capillary discharge pumped soft-x-ray amplifier. Two-dimensional near-field and far-field measurements were obtained over a wide range of discharge parameters. The spot size and divergence of the laser beam were observed to increase significantly with decreasing discharg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of vision
دوره 12 2 شماره
صفحات -
تاریخ انتشار 2012