Improved cine cardiovascular magnetic resonance using Clariscan (NC100150 injection).

نویسندگان

  • N H Bunce
  • J C Moon
  • N G Bellenger
  • J Keegan
  • F Grothues
  • J A McCrohon
  • J M Francis
  • G C Smith
  • E D Burman
  • D N Firmin
  • V W Hoffmann
  • D J Pennell
چکیده

We evaluated the use of Clariscan 0.75, 2, and 5 mg Fe/kg body weight in six patients to determine optimal dosing for short repetition time cine imaging. Breathhold cine images were acquired in the vertical and horizontal long axes and the short axis. Blood-pool signal-to-noise ratio increased significantly in all planes (p < 0.01) but was least marked in the short axis. Myocardial signal-to-noise ratio increased by a lesser amount (p < 0.05). Myocardial to blood-pool signal-difference-to-noise ratio improved significantly in the long axes (p < 0.05) and was greatest at 2 mg Fe/kg body weight, but changes in the short axis were minor. With the 5-mg Fe/kg body weight dose, the response was reduced or reversed due to T2* effects. Visual assessment improved in all planes (p < 0.05) and was optimal at 2 mg Fe/kg body weight. In conclusion, Clariscan improves short repetition time cardiac breathhold cine imaging, particularly in the long axis planes, with an optimal dose of 2 mg Fe/kg body weight.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of the intravascular contrast agent NC100150 injection in spin-echo and gradient-echo imaging of the heart.

This is the first study of the intravascular iron oxide particle contrast agent, NC100150 Injection (Nycomed Imaging AS, Oslo, Norway, a part of Nycomed Amersham) in magnetic resonance imaging of the human heart. Eighteen healthy male volunteers were studied at both 0.5 and 1.5 T before and after the administration of NC100150 Injection. Transaxial spin-echo images were acquired at both field s...

متن کامل

Evaluation of a new ultrasmall superparamagnetic iron oxide contrast agent Clariscan, (NC100150) for MRI of renal perfusion: experimental study in an animal model.

PURPOSE To determine the diagnostic value of a new ultrasmall superparamagnetic iron oxide Clariscan, (NC100150) for the evaluation of renal perfusion in an animal model using a 3D-FFE-EPI sequence. MATERIALS AND METHODS Four groups of four rabbits each were imaged after bolus injection of NC100150, using a 1.5 T MR system (Gyroscan ACS-NT). T2*w MR images in the coronal plane were acquired o...

متن کامل

High-resolution magnetic resonance coronary angiography of the entire heart using a new blood-pool agent, NC100150 injection: comparison with invasive x-ray angiography in pigs.

Recent developments of novel magnetic resonance intravascular contrast agents with low T1 in blood and a long intravascular half-life will rapidly position magnetic resonance coronary angiography (MRCA) at the threshold of clinical application. This article describes the use of one such intravascular contrast agent for noninvasive coronary angiography and comparison with routine invasive x-ray ...

متن کامل

The Characteristics of Vascular Growth in VX2 Tumor Measured by MRI and Micro-CT

Blood supply is crucial for rapid growth of a malignant tumor; medical imaging can play an important role in evaluating the vascular characterstics of tumors. Magnetic resonance imaging (MRI) and micro-computed tomography (CT) are able to detect tumors and measure blood volumes of microcirculation in tissue. In this study, we used MR imaging and micro-CT to assess the microcirculation in a VX2 ...

متن کامل

Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance

BACKGROUND Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 2001