Extending GRAPPA kernels to 4D: application on time-resolved 3D phase contrast imaging

نویسندگان

  • B. A. Jung
  • S. Bauer
  • M. Markl
چکیده

Fig.4: Velocity time courses in a small region-ofinterest in the descending aorta for different reconstruction types. Fig.5: Exemplary plot of pixel-wise velocities of full k-space data vs. PEAKGRAPPA with a 4D-kernel with Rnet=7.2. R Rnet NACS RMSE [%] r2 GRAPPA 4 2.4 24*48 22.6 0.38 PEAK 3D-kernel 8 7.2 12*8 8.7 0.95 PEAK 4D-kernel 8 7.2 12*8 8.1 0.93 PEAK 4D-kernel 12 9.5 12*8 10.4 0.89 Extending GRAPPA kernels to 4D: application on time-resolved 3D phase contrast imaging

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-resolved angiography: Past, present, and future.

The introduction of digital subtraction angiography (DSA) in 1980 provided a method for real time 2D subtraction imaging. Later, 4D magnetic resonance (MR) angiography emerged beginning with techniques like Keyhole and time-resolved imaging of contrast kinetics (TRICKS) that provided frame rates of one every 5 seconds with limited spatial resolution. Undersampled radial acquisition was subseque...

متن کامل

Fast dynamic parallel phase contrast MRI with high acceleration factors and optimized SNR

Introduction: Time-resolved phase contrast (PC) MRI is important for many clinical applications and requires fast data acquisition. In order to increase spatiotemporal resolution or reduce total acquisition times, parallel imaging techniques such as kt-SENSE, kt-BLAST [1] and kt-Grappa [2] have been introduced. For kt-BLAST/ kt-SENSE it has been shown that high reduction factors of the order of...

متن کامل

4D flow imaging with MRI.

Magnetic resonance imaging (MRI) has become an important tool for the clinical evaluation of patients with cardiovascular disease. Since its introduction in the late 1980s, 2-dimensional phase contrast MRI (2D PC-MRI) has become a routine part of standard-of-care cardiac MRI for the assessment of regional blood flow in the heart and great vessels. More recently, time-resolved PC-MRI with veloci...

متن کامل

On the optimal acceleration of time-resolved 3D imaging using GRAPPA

Introduction: Time-resolved 3D imaging often suffers from long acquisition times while aiming for high temporal or spatial resolution. To speed up acquisition times parallel imaging techniques for volumetric [1] and time-resolved 2D data acquisition have been introduced [2-4]. However, no systematic investigation of parallel imaging using GRAPPA to reconstruct time-resolved 3D data has been pre...

متن کامل

Accelerated 4D flow imaging using randomly undersampled echo planer imaging with compressed-sensing reconstruction

Introduction 2D phase contrast (PC) CMR is currently the standard clinical imaging sequence for evaluation of blood flow [1]. Recently, 3D time-resolved PC CMR (4D-PC) has been used for quantification and visualization of blood flow in all three directions of a volume [2]. However, such acquisitions require long scan times (often 10-20 minutes), which reduces its clinical feasibility and leads ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008