Does etomidate increase vasopressor requirements in patients needing mechanical ventilation?
نویسندگان
چکیده
BACKGROUND Single-dose etomidate is used as an induction agent for rapid-sequence intubation and is associated with transient adrenal insufficiency. There is ongoing debate as to the clinical consequences of this transient adrenal insufficiency for critically ill patients. OBJECTIVE To determine if the use of etomidate is associated with higher requirements for a vasopressor, relative to other induction agents, at a single time point (24 h after administration of the induction agent) in patients needing mechanical ventilation. METHODS In this retrospective observational study utilizing electronic health records, a convenience sample of 50 patients who had undergone intubation in the emergency department with etomidate were matched (1:1) with patients who had received other induction agents. Matching was based on primary admitting diagnosis relating to the cause of shock, APACHE II (Acute Physiology and Chronic Health Evaluation II) score, age, and sex. All patients were subsequently admitted to critical care areas for management. As a surrogate marker of hemodynamic instability, the vasopressor dose was recorded 24 h after intubation. Vasopressor doses were converted to norepinephrine equivalents for comparison. RESULTS The mean dose of vasopressors, in norepinephrine equivalents, was 4 μg/min(-1) for patients receiving etomidate and 3 μg/min(-1) for the control group (mean difference 0.7 μg min(-1), 95% confidence interval [CI] -1.9 to 3.2 μg min(-1), p = 0.61). Twelve of the patients in the etomidate group and 16 of those in the control group required the use of vasopressors at 24 h following intubation (odds ratio 2.3, 95% CI 0.53 to 13.99, p = 0.34). CONCLUSIONS Single-dose etomidate does not adversely affect hemodynamic stability, as measured by the dose of vasopressors required at 24 h after administration.
منابع مشابه
Single-dose etomidate is not associated with increased mortality in ICU patients with sepsis: analysis of a large electronic ICU database.
OBJECTIVE Retrospective analyses of several trials suggest etomidate may be unsafe for intubation in patients with sepsis. We evaluated the association of etomidate and mortality in a large cohort of septic patients to determine if single-dose etomidate was associated with increased in-hospital mortality. DESIGN AND SETTING Retrospective cohort study at the Philips eICU Research Institute ICU...
متن کاملA touch of cooling may help
CITATION Schortgen F, Clabault K, Katsahian S, Devaquet J, Mercat A, Deye N, Dellamonica J, Bouadma L, Cook F, Beji O, Brun-Buisson C, Lemaire F, Brochard L: Multicenter randomized controlled clinical trial of fever control by external cooling to diminish vasopressor requirements in septic shock. Assistance Publique-Hôpitaux de Paris, France. Am J Respir Crit Care Med 2012, 185:1088-1095. BAC...
متن کاملSingle induction dose of etomidate versus other induction agents for endotracheal intubation in critically ill patients.
BACKGROUND The use of etomidate for emergency airway interventions in critically ill patients is very common. In one large registry trial, etomidate was the most commonly used agent for this indication. Etomidate is known to suppress adrenal gland function, but it remains unclear whether or not this adrenal gland dysfunction affects mortality. OBJECTIVES The primary objective was to assess, i...
متن کاملEffect of induction agent on vasopressor and steroid use, and outcome in patients with septic shock
INTRODUCTION In seriously ill patients, etomidate gives cardiovascular stability at induction of anaesthesia, but there is concern over possible adrenal suppression. Etomidate could reduce steroid synthesis and increase the need for vasopressor and steroid therapy. The outcome could be worse than in patients given other induction agents. METHODS We reviewed 159 septic shock patients admitted ...
متن کاملClinical experience with a pumpless extracorporeal lung assist device.
We present three patients with respiratory failure in whom conventional mechanical lung ventilation resulted in unacceptably high levels of carbon dioxide, severe acidosis and high vasopressor requirements. A pumpless arteriovenous extracorporeal carbon dioxide removal device (Novalung) was inserted. Arterial carbon dioxide levels were reduced rapidly with a corresponding increase in pH, reduct...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Canadian journal of hospital pharmacy
دوره 65 4 شماره
صفحات -
تاریخ انتشار 2012