Trace elemental analysis of commercial bottled drinking water by a portable total reflection X-ray fluorescence spectrometer.

نویسندگان

  • Shinsuke Kunimura
  • Jun Kawai
چکیده

A portable total reflection X-ray fluorescence spectrometer was applied to commercial bottled drinking water containing 62 ppb (microg/L) V, 7.5 ppm (mg/L) Ca, and 1 ppm K. A dry residue, prepared by repeated pipetting and drying a 20 microL portion of drinking water on a sample holder six times, and another dry residue, prepared by pipetting and drying a 120 microL portion of the drinking water, were measured. The size of the dry residue of the drinking water was reduced by repeating the pipetting and drying. Calcium and potassium were easily detected in these two dry residues. Vanadium was detected in the dry residue prepared by repeated pipetting and drying. Vanadium, calcium, and potassium were quantified by using an internal standard, and the average quantified concentrations of V, Ca, and K were 91 ppb, 8.2 ppm, and 1.5 ppm, respectively. Although these quantified concentrations deviated from the certified concentrations (62 ppb of V, 7.5 ppm of Ca, and 1 ppm of K), it was possible for this portable spectrometer to estimate approximate concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of a portable total reflection X-ray fluorescence spectrometer for field investigation

A newly developed, portable total reflection X-ray fluorescence (TXRF) spectrometer was tested during a field campaign on Chilean lakes and a German river in January 2002. The field measurements were compared with laboratory measurements carried out on a stationary instrument in the German laboratory. For method validation certified reference material (NIST SRM 1640 Trace elements in natural wa...

متن کامل

Environmental trace-element analysis using a benchtop total reflection X-ray fluorescence spectrometer.

Total reflection X-ray fluorescence (TXRF) analysis is an established technique for trace-element analysis in various types of samples. Though expensive large-scale systems restricted the applications in the past, in this study the capability of a benchtop system for trace elemental analysis is reported. The suitability of this system for the mobile on-site analysis of heavy metal contaminated ...

متن کامل

Application of a Portable Txrf Spectrometer to Determine Trace Amounts of Toxic Elements

Using a portable total reflection X-ray fluorescence spectrometer, a sample containing 100 pg each of 3d transition metals, 500 pg of As, and 1 ng each of Sr, Y, and Zr is measured. Although non-monochromatic X-rays from a 5 W X-ray tube (Tube voltage: 25 kV) are used, the trace amounts of these elements are detected. This portable spectrometer is applied to analysis of river water, a leaching ...

متن کامل

Multi-element analysis by portable total reflection X-ray fluorescence spectrometer.

Multi-element solutions containing the 11 elements S, K, Sc, V, Mn, Co, Cu, Ga, As, Br and Y were analyzed by a portable total reflection X-ray fluorescence (TXRF) spectrometer. The excitation parameters (glancing angle, operational voltage and current) and sample amount were optimized for the portable TXRF in order to realize the smallest possible detection limits for all elements. The excitat...

متن کامل

Development and characterization of a portable total reflection X-ray fluorescence system using a waveguide for trace elements analysis.

This paper presents a portable total reflection X-ray fluorescence system composed of a 15 W X-ray tube, with a gold anode, a waveguide constituted by two Perspex(®) parallel plates, a Si PIN detector and a quartz optical flat. The critical angle of the total reflection system was experimentally determined by measuring a zinc solution (100 mg/L). The accuracy of the system was checked using SRM...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 23 10  شماره 

صفحات  -

تاریخ انتشار 2007