Tensile and shear loading stability of all-inside meniscal repairs: an in vitro biomechanical evaluation.

نویسندگان

  • Peter U Brucker
  • Philippe Favre
  • Gabor J Puskas
  • Arndt von Campe
  • Dominik C Meyer
  • Peter P Koch
چکیده

BACKGROUND Most biomechanical studies for evaluation of the structural properties of meniscal repairs have been performed in tensile loading scenarios perpendicular to the circumferential meniscal fibers. However, meniscal repair constructs are also exposed to shear forces parallel to the circumferential meniscal fibers during healing, particularly in the midportion of the meniscus. HYPOTHESIS Material properties of meniscal repair devices cannot be extrapolated from tensile to shear load scenarios. STUDY DESIGN Controlled laboratory study. METHODS In 84 harvested and isolated bovine lateral menisci following removal of adjacent soft tissue, a standardized vertical lesion was set followed by repair using all-inside flexible (FasT-Fix, FasT-Fix AB, RapidLoc) and rigid (Meniscus Screw, Meniscus Arrow) meniscal repair devices. Vertical and horizontal 2.0 Ethibond sutures were used as controls. The repaired meniscal construct was tested in a tensile (parallel to the axis of the tested repair device) and shear load scenario (perpendicular to the axis of the tested repair device) at 5 mm/min and 37 degrees C environmental temperature. Maximum load to failure, stiffness, and failure mode were recorded. RESULTS The absolute load to failure values of each repair device in the shear scenario were only marginally different from the tensile load scenario. However, the stiffness of several tested devices was markedly reduced in the shear scenario. In both scenarios, large differences of the load to failure and the stiffness between the implant types up to 5-fold were found (P < .05). The failure mode of several all-inside flexible repair devices was different in the shear versus tensile load scenario, while the failure mode of the rigid systems was similar in both scenarios. CONCLUSION All-inside meniscal repair devices exposed to shear load scenarios have comparable maximum loads to failures as tensile load scenarios. However, the stiffness of the majority of the flexible meniscal repair implants in a shear load scenario is markedly reduced. The applied scenario also affects the failure mode in several flexible meniscal repair devices. CLINICAL RELEVANCE Meniscal repair devices with sufficient stiffness and stability against shear loads may be favored for meniscal repair, especially within the midportion of the meniscus where shear loads occur during healing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A biomechanical evaluation of all-inside 2-stitch meniscal repair devices with matched inside-out suture repair.

BACKGROUND Many all-inside suture-based devices are currently available, including the Meniscal Cinch, FasT-Fix, Ultra FasT-Fix, RapidLoc, MaxFire, and CrossFix System. These different devices have been compared in various configurations, but to our knowledge, the Sequent meniscal repair device, which applies running sutures, has not been compared with the Ultra FasT-Fix, nor has it been compar...

متن کامل

Biomechanical Loading Evaluation of Unsintered Hydroxyapatite/poly-l-lactide Plate System in Bilateral Sagittal Split Ramus Osteotomy

OSTEOTRANS MX® (Takiron Co., Ltd., Osaka, Japan) is a bioactive resorbable maxillofacial osteosynthetic material composed of an unsintered hydroxyapatite/poly-l-lactide composite, and its effective osteoconductive capacity has been previously documented. However, the mechanical strength of this plate system is unclear. Thus, the aim of this in vitro study was to assess its tensile and shear str...

متن کامل

All-inside Arthroscopic Meniscal Repair Technique Using a Midbody Accessory Portal

Treatment of symptomatic meniscal tears continues to evolve as we improve our understanding of the biomechanical role of the meniscus and its long-term importance to the health of the knee joint. Suture repair of meniscal tears is challenging, yet the incidence of repairs among our colleagues continues to rise as we aim to preserve meniscal tissue. Many elements of performing a repair are tedio...

متن کامل

Biomechanical testing of transcapsular meniscal repair

BACKGROUND All of previous biomechanical studies on meniscal repair have examined the meniscus itself without synovial membrane and capsule, although in the clinical setting, the meniscal repair is generally performed including capsule. Therefore, biomechanical properties of transcapsular meniscal repair are unclear. Thus, this study aimed to clarify the biomechanical properties of transcapsula...

متن کامل

Human Mesenchymal Stem Cell-derived Exosomes Promote Orderly Cartilage Regeneration in an Immunocompetent Rat Osteochondral Defect Model

Background : Although meniscal repair techniques have developed for several decades, meniscal repair of radial tears still remains challenging issue. For successful meniscal healing of radial tears, primary mechanical stability of meniscal repair is one of the essential requirements. All-inside vertical suture and Cross-suture techniques have been reported to provide superior stability compared...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of sports medicine

دوره 38 9  شماره 

صفحات  -

تاریخ انتشار 2010