Letter to the Editor regarding "Achieving comparability with IFCC reference method for the measurement of hemoglobin A1c by use of an improved isotope-dilution mass spectrometry method".
نویسندگان
چکیده
The development of reference measurement methods for hemoglobin A1c (HbA1c) is important for quality assurance in diabetes management. The IFCC reference method using purified proteins as calibration standards is the recommended accuracy-based reference method for the standardization of HbA1c measurement. We developed a highly precise and accurate liquid chromatography-isotope-dilution tandem mass spectrometry (LC-IDMS/MS) procedure, which can serve as an alternative accuracy-based method for HbA1c measurement. In this method, enzymatic proteolysis was applied to sample preparation, followed by LC-IDMS/MS measurement of hemoglobin A0 (HbA0) and HbA1c, using two "signature" hexapeptides for calibration. The concentrations of the signature hexapeptide calibration solutions were, in turn, determined using a hydrolysis method with HCl, followed by LC-IDMS/MS measurement using amino acid solutions as calibration standards. These solutions were gravimetrically prepared from pure amino acid certified reference materials (CRMs). The developed LC-IDMS/MS method was used in participation in an IFCC ring trial for reference laboratories (RELA 2013 and 2014) for HbA1c, where our results were compared with those using the IFCC reference method. The deviations were found to be 0.4-1.7 mmol mol(-1) [or 0.04-0.16% in National Glygohemoglobin Standardization Program (NGSP) units], revealing good comparability with the IFCC reference method. The relative expanded uncertainty of the LC-IDMS/MS was in the range of 2.6% to 2.8% (1.6% to 2.2% after converting to NGSP units). With excellent method precision, good comparability with the IFCC reference method, and a small measurement uncertainty, the developed LC-IDMS/MS method may be used as an alternative accuracy-based reference method for HbA1c measurement.
منابع مشابه
Improved reference measurement method for hemoglobin A1c by use of liquid chromatography-isotope dilution-tandem mass spectrometry.
We have developed an improved reference measurement method for hemoglobin A1c (Hb A1c) 1 based on liquid chromatography–isotope dilution–tandem mass spectrometry (LC-ID-MS/MS) with traceability to the SI unit. The method has a small measurement uncertainty (MU) and gives results in good agreement with the accuracy-based IFCC reference method. Kaiser et al. (1 ) demonstrated the possibility of u...
متن کاملCardiac troponin testing is overused after the rule-in or rule-out of myocardial infarction.
(type A MU) is one of the major components in overall MU. It is possible to achieve a small MU by improving the imprecision of the sample preparation procedure. Other than ensuring complete proteolysis, we observed that adding the isotope-labeled internal standard before pro-teolysis provided better imprecision than after proteolysis. This may allow a better control of the isotope ratio through...
متن کاملApplicability of common reference intervals for serum creatinine concentrations to the Croatian population.
BACKGROUND In accordance with an ongoing activity for worldwide harmonization based on traceability in laboratory methods, the goal of this study was to validate the applicability of recommended "common" reference intervals for serum creatinine concentrations using a specific enzymatic method to the Croatian population. METHODS The reference group consisted of 240 healthy subjects (120 males ...
متن کاملModified HPLC-electrospray ionization/mass spectrometry method for HbA1c based on IFCC reference measurement procedure.
BACKGROUND Monitoring of hemoglobin A(1c) (HbA(1c)) is important in the management of diabetes. The IFCC reference measurement procedure for HbA(1c) is based on the ratio of glycated to nonglycated N-terminal hexapeptides of the beta-chains of hemoglobin after digestion with Glu-C endoproteinase. We developed a modification of the original reference measurement procedure with HPLC-electrospray ...
متن کاملStandardization of Hemoglobin
To the Editor: Kobold et al. (1) describe candidate reference methods for hemoglobin A1c (HbA1c) that are based on the identification of hexapeptides from the N-terminus of the b-chains by both a mass spectrometry technique and capillary electrophoresis. Although they are to be congratulated on their efforts in this regard, I wonder whether the (IFCC) definition of HbA1c as hemoglobin modified ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical and bioanalytical chemistry
دوره 409 24 شماره
صفحات -
تاریخ انتشار 2015