Particulate Suspension Blood Flow through a Stenosed Catheterized Artery
نویسندگان
چکیده
The flow of blood through a narrow catheterized artery with an overlapping stenosis has been investigated. To account for the presence of red cells, blood has been represented by a macroscopic two-phase model (i.e., a suspension of erythrocytes in plasma). The expression for the flow characteristics-the flow rate, the impedance (resistance to flow), the wall shear stress in the stenotic region, the shear stresses at the stenosis two throats and at critical height of the stenosis, has been derived. It is found that the impedance increases with the catheter size, with the hematocrit and also with the stenosis size (height and length). A significant increase in the magnitude of the impedance and other flow characteristics occur even for a small increase in the catheter size. Variations in the magnitude of all the flow characteristics are observed to be similar in nature with respect to any parameter given.
منابع مشابه
An implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery
With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...
متن کاملMathematical modeling of blood flow in a stenosed artery under MHD effect through porous medium
In this investigation, a mathematical model for studying oscillatory flow of blood in a stenosed artery under the influence of transverse magnetic field through porous medium has been developed. The equations of motion of blood flow are solved analytically. The analytical expressions for axial velocity, volumetric flow rate, pressure gradient, resistance to blood flow and shear stress have been...
متن کاملOscillatory MHD Flow of Blood through an Artery with Mild Stenosis (RESEARCH NOTE)
The purpose of this work is to study the effect of oscillatory MHD blood flow in stenosed artery. The analytical and numerical results are obtained for oscillatory MHD blood flow, which is assumed to be a Newtonian fluid. It was also assumed that the surface roughness is of cosine shaped and the maximum height of roughness is negligible, compared with the radius of un-constricted tube. The flui...
متن کاملEffects of Hematocrit on Impedance and Shear Stress during Stenosed Artery Catheterization
The flow of blood through a stenosed catheterized artery has been studied. To observe the effects of hematocrit, blood has been represented by a two-phase macroscopic model (i.e., a suspension of red cells in plasma). It is found that for any given catheter size, the impedance increases with hematocrit and also for a given hematocrit, the same increases with the catheter size. In the stenotic r...
متن کاملNumerical Modeling of Two-Layered Micropolar Fluid Through an Normal and Stenosed Artery
In the present work a two fluid model for blood flow through abnormally constrictedhuman artery (stenosed artery) has been developed. The model consists of a core region of suspensionof all erythrocytes assumed to be micro-polar fluid so as to include the micro-structural effects inaddition to the peripheral-layer viscosity effects, and a peripheral plasma layer free from cells of anykind of Ne...
متن کامل