Investigations on the Energy Efficiency of Stratified Air Distribution Systems with Different Diffuser Layouts
نویسندگان
چکیده
Yuanda Cheng 1,*, Jinming Yang 1,*, Zhenyu Du 1 and Jinqing Peng 2 1 College of Environmental Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China; [email protected] 2 College of Civil Engineering, Hunan University, Changsha 410082, China; [email protected] * Correspondence: [email protected] (Y.C.); [email protected] (J.Y.); Tel.: +86-351-317-3586 (Y.C.)
منابع مشابه
Effect of opening diffuser and return vent location on air quality, thermal comfort and energy saving in desk displacement ventilation (DDV) system
Many investigations have recently been performed on return vent height and indicate that having 1.3 m distance from the floor is the optimized height for it. In this article, the effect of distance between opening diffuser and return vent on air quality, thermal comfort and energy saving was investigated. According to the results, by increasing the distance between opening and return vent up to...
متن کاملPerformance Evaluation of A Stratified Chilled- Water Thermal Storage System
In countries with hot climates, air-conditioning forms a large proportion of annual peak electrical demand, requiring expansion of power plants to meet the peak demand, which goes unused most of the time. Use of well-designed cool storage can offset the peak demand to a large extent. In this study, an air conditioning system with naturally stratified storage tank was designed, constructed and t...
متن کاملDesign of Air Distribution System for Operation Theatre Using Flow Visualization Techniques to Improve Flow Characteristics
Operation Theatre (OT) is the most important area where precise controlled on indoor air quality is required because it is directly related to patient health and its recovery period. This work aims to study and visualize the airflow distribution of conventional flat air diffuser ventilation system and newly designed angular air ventilation system in OT. Angular Air Distribution (AAD) system is ...
متن کاملEnergy and Second Law of Thermodynamics Analysis of Shower Cooling Tower with Variation in Inlet Air Temperature
A shower cooling tower (SCT) operates without fill because of salt decomposition on the fill that leads to deterioration of conventional cooling tower performance. This study presents a two-dimensional mathematical model for energy and exergy analysis of multi-diameter droplets and air interaction along with the height of the forced draft SCT, to predict the exit condition of water droplet for ...
متن کاملNumerical and Experimental Investigations for Design of a High Performance Micro-hydro-kinetic Turbine
Design and manufacturing of a high performance micro-hydro-kinetic turbine is discussed in the present paper. The main goal is manufacturing an equipped experimental model of hydro-kinetic turbine with highest energy absorption from water current. A multi-shape ducted turbine comprised of a multi-part diffuser was manufactured that can be converted to many experimental models for studying vario...
متن کامل