Undersampled projection reconstruction applied to MR angiography.

نویسندگان

  • D C Peters
  • F R Korosec
  • T M Grist
  • W F Block
  • J E Holden
  • K K Vigen
  • C A Mistretta
چکیده

Undersampled projection reconstruction (PR) is investigated as an alternative method for MRA (MR angiography). In conventional 3D Fourier transform (FT) MRA, resolution in the phase-encoding direction is proportional to acquisition time. Since the PR resolution in all directions is determined by the readout resolution, independent of the number of projections (Np), high resolution can be generated rapidly. However, artifacts increase for reduced Np. In X-ray CT, undersampling artifacts from bright objects like bone can dominate other tissue. In MRA, where bright, contrast-filled vessels dominate, artifacts are often acceptable and the greater resolution per unit time provided by undersampled PR can be realized. The resolution increase is limited by SNR reduction associated with reduced voxel size. The hybrid 3D sequence acquires fractional echo projections in the k(x)-k(y) plane and phase encodings in k(z). PR resolution and artifact characteristics are demonstrated in a phantom and in contrast-enhanced volunteer studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D-Rotational Phase-Contrast MR Angiography

Introduction For many applications of MRI angiography (MRA), high spatial resolution images obtained in reasonable scan times are required. For significantly decreasing the image acquisition time, projection reconstruction based approaches have been proposed, using highly undersampled two-dimensional projections [1,2]. These methods have e.g. been successfully applied to temporally resolved MRA...

متن کامل

Time-resolved angiography: Past, present, and future.

The introduction of digital subtraction angiography (DSA) in 1980 provided a method for real time 2D subtraction imaging. Later, 4D magnetic resonance (MR) angiography emerged beginning with techniques like Keyhole and time-resolved imaging of contrast kinetics (TRICKS) that provided frame rates of one every 5 seconds with limited spatial resolution. Undersampled radial acquisition was subseque...

متن کامل

Parameter-Free Reconstruction of Highly Undersampled MR Angiography Images using Gradient Descent with Sparsification

Figure 2: Time curves for representative pixels in the carotid artery (left) and sagittal sinus (center) for the undersampled (dotted) and GraDes reconstruction (solid). The GraDes reconstruction follows the temporal dynamics shown by the undersampled data closely. Additionally, the enhancement of the carotid artery occurs significantly before that of the sagittal sinus in the GraDes reconstruc...

متن کامل

Vastly undersampled Isotropic Projection Reconstruction and HYPR for Time Resolved CE-MRA of the Peripheral Vessels

Introduction Vastly undersampled Isotropic Projection Reconstruction (VIPR) [1] techniques have been successfully utilized for time-resolved contrast-enhanced MR angiography (CE-MRA) studies. There are several benefits of a VIPR k-space trajectory, including the more benign nature of undersampling artifacts, which can facilitate higher undersampling factors. Due to the geometry of the legs, how...

متن کامل

Magnetic Resonance in Medicine 57:764–775 (2007) Projection Reconstruction MR Imaging Using FOCUSS

The focal underdetermined system solver (FOCUSS) was originally designed to obtain sparse solutions by successively solving quadratic optimization problems. This article adapts FOCUSS for a projection reconstruction MR imaging problem to obtain high resolution reconstructions from angular undersampled radial k -space data. We show that FOCUSS is effective for projection reconstruction MRI, sinc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 43 1  شماره 

صفحات  -

تاریخ انتشار 2000