INR Activity in Development and Production of Bunch Shape Monitors

نویسندگان

  • S. K. Esin
  • A. V. Feschenko
  • P. N. Ostroumov
چکیده

Precise measurements of the longitudinal profiles of ion beams with ∼10 ps temporal resolution became available with the help of a Bunch Shape Monitor (BSM) developed and used at the INR. A number of BSMs have been developed, fabricated at the INR and tested with a beam at several laboratories during last 3 years. The upgraded BSM-Bunch Length and Velocity Detector (BLVD)-can measure not only longitudinal profile but also absolute beam velocity. A 3DBSM is a further improvement of the monitor which allows a three-dimensional density distribution of the bunched beam to be measured.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ar X iv : p hy si cs / 0 00 81 15 17 A ug 2 00 0 SPACE CHARGE EFFECTS IN BUNCH SHAPE MONITORS

The operation and parameters of Bunch Shape Monitors using coherent transformation of time structure of an analyzed beam into a spatial one of low energy secondary electrons emitted from a wire target is influenced by the characteristics of a beam under study. The electromagnetic field of a bunch disturbs the trajectories of secondary electrons, thus resulting in a degradation of phase resoluti...

متن کامل

Novel Single Shot Bunch Length Diagnostic Using Coherent Diffraction Radiation

Current beam bunch length monitors that measure the spectral content of beam-associated coherent radiation to determine the longitudinal bunch form factor usually require wide bandwidth detection, Fourier transformation of spectral or interferometric data, phase retrieval algorithms and multiple beam pulses to obtain the bunch length. In this paper we discuss progress in the development of a no...

متن کامل

Point-of-care International Normalised Ratios: UK NEQAS experience demonstrates necessity for proficiency testing of three different monitors.

External quality assessment (EQA) or proficiency testing is widely considered to be necessary for International Normalised Ratio (INR) determinations performed in conventional laboratory settings. There is increasing use of near-patient-test (NPT) or point-of-care (POC) INR devices and it is not known whether EQA is also necessary for these monitors. We report here on six years experience of pr...

متن کامل

Review of Diagnostics for next Generation Linear Accelerators

New electron linac designs incorporate substantial advances in critical beam parameters such as beam loading and bunch length and will require new levels of performance in stability and phase space control. In the coming decade, e(and e+) linacs will be built for a high power linear collider (TESLA, CLIC, JLC/NLC), for fourth generation X-ray sources (TESLA FEL, LCLS, Spring 8 FEL) and for basi...

متن کامل

Shape Selective Pillared Clay Catalysts for P-Xylene Production

Shape selective xylene production is very important in the polymer industry because of its extensive use as raw material for monomer preparation. The acidity associated with the Lewis and Broensted centers present in the pillars interlayered clay and its textural properties allows good catalytic activity and shape selectivity toward p-xylene production. So, in the present study, ultrasonic and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1995