Pre-Operative Right Ventricular Dysfunction Is Associated With Gastrointestinal Bleeding in Patients Supported With Continuous-Flow Left Ventricular Assist Devices.
نویسندگان
چکیده
OBJECTIVES This study sought to determine whether severe right ventricular (RV) dysfunction in the pre-operative setting is associated with an increased risk of gastrointestinal bleeding (GIB) post-left ventricular assist device (LVAD). BACKGROUND GIB is a significant complication in patients supported with continuous-flow LVADs. The impact of RV dysfunction on the risk of GIB has not been investigated. METHODS We retrospectively identified 212 patients who survived index hospitalization after implantation of HeartMate II (Thoratec Corp., Pleasanton, California) or Heartware HVAD (HeartWare Corp., Framingham, Massachusetts) from June 2009 to April 2013. Patients with severe RV dysfunction on pre-LVAD echocardiogram (n = 37) were compared to patients without severe RV dysfunction (n = 175). The primary outcome was freedom from GIB. RESULTS The majority of patients were male (79%) with a median INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) profile of 2 at LVAD implantation. There were no significant differences between cohorts with respect to demographics, comorbidities, device type, international normalization ratio, or aspirin strategy. During follow-up, 81 patients had GIB events: 23 of 37 (62%) in the severe RV dysfunction group versus 58 of 175 (33%) in the control group (p = 0.001). After adjustment for age and ischemic cardiomyopathy, severe RV dysfunction was associated with increased risk of GIB (hazard ratio: 1.799, 95% confidence interval: 1.089 to 2.973, p = 0.022). CONCLUSIONS In this single-center sample of patients supported with continuous-flow LVADs, severe RV dysfunction on pre-LVAD echocardiogram was associated with an increased risk of GIB. Further studies are needed to investigate possible mechanisms by which RV dysfunction increases the risk of GIB and to identify patient populations who may benefit from alterations in antithrombotic strategies.
منابع مشابه
Bleeding with the artificial heart: Gastrointestinal hemorrhage in CF-LVAD patients
Continuous-flow left ventricular assist devices (CF-LVADs) have significantly improved outcomes for patients with end-stage heart failure when used as a bridge to cardiac transplantation or, more recently, as destination therapy. However, its implantations carries a risk of complications including infection, device malfunction, arrhythmias, right ventricular failure, thromboembolic disease, pos...
متن کاملGastrointestinal bleeding with continuous-flow left ventricular assist devices.
Continuous-flow left ventricular assist device (CF-LVAD) insertion is a life-saving procedure that is being increasingly used in patients with advanced heart failure. However, patients with CF-LVADs are at an increased risk of gastrointestinal bleeding (GIB). Bleeding can occur anywhere in the GI tract with lesions being more prevalent in the upper GI tract than in the lower GI tract. The patho...
متن کاملImaging for ventricular function and myocardial recovery on nonpulsatile ventricular assist devices.
Advances in the field of device support have led to increased use of continuous-flow left ventricular assist devices (LVADs) to improve outcomes in patients with end-stage heart disease. Newer-generation LVADs have become the pump of choice for bridging to heart transplantation and as destination therapy for patients with contraindications to transplantation.1 Different imaging modalities have ...
متن کاملMulticenter Evaluation of Octreotide as Secondary Prophylaxis in Patients With Left Ventricular Assist Devices and Gastrointestinal Bleeding.
BACKGROUND Gastrointestinal (GI) bleeding is one of the most common complications after continuous-flow left ventricular assist device implantation. More than one third of patients with incident bleed go on to develop recurrent GI bleeding. Octreotide, a somatostatin analog, is proposed to reduce the risk of recurrent GI bleeding in this population. METHODS AND RESULTS This multicenter, retro...
متن کاملPulsatility and the risk of nonsurgical bleeding in patients supported with the continuous-flow left ventricular assist device HeartMate II.
BACKGROUND Bleeding is an important cause of morbidity and mortality in patients with continuous-flow left ventricular assist devices (LVADs). Reduced pulsatility has been implicated as a contributing cause. The aim of this study was to assess the effects of different degrees of pulsatility on the incidence of nonsurgical bleeding. METHODS AND RESULTS The Utah Transplantation Affiliated Hospi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JACC. Heart failure
دوره 3 12 شماره
صفحات -
تاریخ انتشار 2015