Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics

نویسندگان

  • Toru Tanimori
  • Yoshitaka Mizumura
  • Atsushi Takada
  • Shohei Miyamoto
  • Taito Takemura
  • Tetsuro Kishimoto
  • Shotaro Komura
  • Hidetoshi Kubo
  • Shunsuke Kurosawa
  • Yoshihiro Matsuoka
  • Kentaro Miuchi
  • Tetsuya Mizumoto
  • Yuma Nakamasu
  • Kiseki Nakamura
  • Joseph D. Parker
  • Tatsuya Sawano
  • Shinya Sonoda
  • Dai Tomono
  • Kei Yoshikawa
چکیده

Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, which would be, for nuclear MeV gammas, only possible via complete reconstruction of the Compton process. Recently we have revealed that "Electron Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function (PSF). The information of an incoming gamma is kept along a ray with the PSF and that is equivalent to geometrical optics. Here we present an imaging-spectroscopic measurement with the ETCC. Our results highlight the intrinsic difficulty with CCs in performing accurate imaging, and show that the ETCC surmounts this problem. The imaging capability also helps the ETCC suppress the noise level dramatically by ~3 orders of magnitude without a shielding structure. Furthermore, full reconstruction of Compton process with the ETCC provides spectra free of Compton edges. These results mark the first proper imaging of nuclear gammas based on the genuine geometrical optics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First On-Site True Gamma-Ray Imaging-Spectroscopy of Contamination near Fukushima Plant

We have developed an Electron Tracking Compton Camera (ETCC), which provides a well-defined Point Spread Function (PSF) by reconstructing a direction of each gamma as a point and realizes simultaneous measurement of brightness and spectrum of MeV gamma-rays for the first time. Here, we present the results of our on-site pilot gamma-imaging-spectroscopy with ETCC at three contaminated locations ...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

Study of Geometrical-Dependence of Glow Discharge on Gain Coefficient in a TE-N2 Laser

Based on a set of experiments, using a transversely exited (TE) oscillator-amplifier N2-laser system (OSC-AMP) with the AMP effective length of 31cm, measurements have been carried out for small signal gain, g0, and saturation energy density, Es, for different AMP gap separations. It was found that the gain-value depends on the AMP electrode gap separation, d<su...

متن کامل

Imaging of accidental contamination with F-18-solution; a quick trouble-shooting procedure

 To the best of our knowledge, imaging of accidental exposure to radioactive fluorine-18 (F-18) due to liquid spill has not been described earlier in the scientific literature. The short half-life of F-18 (t½=110 min), current radiation safety requirements, and Good Manufacturing Practice (GMP) regulations on radiopharmaceuticals have restrained the occurrence of these incidents. The possibilit...

متن کامل

Assessment of environmental high-doses using Raman spectroscopy of gamma irradiated MWCNT-OH Nanopowder utilized in radiation accidents

Introduction: The functionalized Multi-Walled Carbon Nanotube with hydroxyl group (MWCNT-OH) due to high aspect ratios (length to diameter), and also excellent mechanical, electrical and thermal characteristics, has great potential applications in flexible electronics, solar cells, antistatic devices, electromagnetic interference shielding, radiation shielding, electrode materi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017