چکیده

BACKGROUND Although bioresorbable scaffolds offer potential advantages compared with metallic drug-eluting stents in the treatment of complex coronary bifurcation lesions, there are concerns that the polymeric scaffold integrity may be compromised. This in vivo study sought to provide insights about the feasibility of performing complex bifurcation stenting with Absorb bioresorbable vascular scaffolds (Abbott Vascular, Santa Clara, CA). METHODS AND RESULTS Twenty New Zealand white rabbits underwent stenting of the nondiseased aortoiliac bifurcation with bioresorbable vascular scaffolds using provisional (PS, n=5), culotte (n=5), modified-T (n=5), or T-and protrusion (n=5) stenting techniques. Angiography, optical coherence tomography, and microcomputed tomography were performed. Angiographic results were excellent without evidence of dissection or side branch (SB) compromise. PS optimally opened the SB ostium without deforming the main vessel (MV) bioresorbable vascular scaffolds, avoiding malapposition, and revealing a single connector fracture in 1 of 5 cases on microcomputed tomography. Culotte stenting resulted in complete bifurcation coverage with extensive segments of double-layered struts and inappropriately apposed struts at the bifurcation level in 3 of 5 cases. On microcomputed tomography, there was MV and SB scaffold distortion at the bifurcation with single strut fractures in 4 of 5 and double fractures in 1 of 5. Modified-T and T-and protrusion resulted in complete bifurcation coverage and in minimal double-strut layers at the neocarina. On microcomputed tomography, no strut fractures were present after modified-T, whereas in 3 of 5 T-and protrusion procedures single strut fractures were noted. CONCLUSIONS Bifurcation stenting using bioresorbable vascular scaffolds is feasible with excellent angiographic results. PS with additional T-and protrusion whenever needed seems a reasonable approach. Whenever a 2-stent technique is planned, modified T-stenting appears the most promising.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Absorb Bioresorbable Vascular Scaffold in Complex Coronary Bifurcation Interventions

Treatment of coronary bifurcation lesions is common in everyday practice and accounts for ≤20% of all percutaneous coronary interventions. The treatment of these lesions with drug-eluting stents, especially when a double-stent technique is used, remains challenging and is associated with a lower procedural success and a higher rate of long-term adverse cardiac events such as stent restenosis an...

متن کامل

Salvage of Side Branch by Provisional “TAP Technique” Using Absorb™ Bioresorbable Vascular Scaffolds for Bifurcation Lesions: First Case Reports with Technical Considerations

Recent technological developments have led to the development of Absorb™ bioresorbable vascular scaffold (BVS) [Abbott Vascular, Santa Clara, USA] for percutaneous treatment of coronary artery disease by percutaneous coronary intervention (PCI). The BVS is now approved for use in many countries but experience in bifurcation lesions is limited and largely unreported and concerns still exist abou...

متن کامل

Novel 3-Dimensional Vessel and Scaffold Reconstruction Methodology for the Assessment of Strut-Level Wall Shear Stress After Deployment of Bioresorbable Vascular Scaffolds From the ABSORB III Imaging Substudy.

A 72-year-old female patient underwent successful deployment of a single 3.0 18 mm Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, California) to the mid right coronary artery (Figures 1A and 1B). The scaffolded segment was imaged simultaneously with coronary angiography and with the C7 Dragonfly (LightLab Imaging Inc., St. Jude Medical, Westford, Massachusetts) optical co...

متن کامل

Bioresorbable polymeric scaffolds for coronary revascularization: Lessons learnt from ABSORB III, ABSORB China, and ABSORB Japan

Bioresorbable polymers and biocorrodible metals are the latest developments in biodegradable materials used in interventional cardiology for the mechanical treatment of coronary atherosclerosis. Poly-L-lactic acid is the most frequently used bioresorbable polymer and initial evidence of feasibility, efficacy and clinical safety following deployment of polymer-based platforms was gained after co...

متن کامل

The absorb bioresorbable vascular scaffold in coronary bifurcations: insights from bench testing.

OBJECTIVES This study sought to evaluate the feasibility of performing contemporary bifurcation techniques with the Absorb everolimus-eluting bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, California) (BVS). BACKGROUND The feasibility of using the BVS in bifurcation lesions is unknown. METHODS We performed bifurcation stenting procedures including main-vessel stenting with b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 9 8  شماره 

صفحات  -

تاریخ انتشار 2016