Access flow measurements in hemodialysis patients: in vivo validation of an ultrasound dilution technique.
نویسندگان
چکیده
In this study, access flow in hemodialysis patients with bridge grafts was measured by a newly developed device. The technique is based on the measurement of changes in the ultrasound characteristics of blood. These changes were initiated by an injection of isotonic saline and measured in the tubes of the extra-corporeal circuit. The access flow rate (mean +/- standard variation) was 880 +/- 440 mL/min (range, 166 to 1740) (N = 46). The mean coefficient of variation was 13.4 +/- 6.8% (median, 13.0%; range 3.5 to 29.4%). Measurements correlated well (r = 0.91, N = 22, P < 0.001) with flow rates determined by magnetic resonance angiography and by a technique based on intra-access flow-pressure curves (r = 0.84, N = 14, P < 0.001). In conclusion, access flow can be measured easily, noninvasively, and reliably by the ultrasound dilution device.
منابع مشابه
Surveillance of Hemodialysis Vascular Access with Ultrasound Vector Flow Imaging
The aim of this study was prospectively to monitor the volume flow in patients with arteriovenous fistula (AVF) with the angle independent ultrasound technique Vector Flow Imaging (VFI). Volume flow values were compared with Ultrasound dilution technique (UDT). Hemodialysis patients need a well-functioning vascular access with as few complications as possible and preferred vascular access is an...
متن کاملValidation in the sheep of an ultrasound velocity dilution technique for haemodialysis graft flow.
BACKGROUND A simple, rapid, inexpensive method for measuring the flow in a patient's vascular access would permit routine monitoring during haemodialysis, and hence provide information of access graft deterioration sufficiently early to increase the success of minimally invasive remedial procedures. This paper reports the validation of such a method in animals. METHODS A PTFE graft was implan...
متن کاملThe measurement of hemodialysis access blood flow by a conductivity step method.
BACKGROUND AND OBJECTIVES Measurement of blood flow rate (Qa) is used to monitor dialysis access, AV fistulas, and grafts. Indicator dilution measurements of the recirculation (R) induced by reversal of hemodialysis blood lines are commonly used. This plus the dialysis circuit flow (Qb) allows calculation of Qa. R also changes the conductivity, which can be measured by a conductivity cell in th...
متن کاملValidation of haemodialysis recirculation and access blood flow measured by thermodilution.
BACKGROUND Recirculation (R) and access blood flow (Qac) measurements are considered useful indicators of adequate delivery of haemodialysis. It was the purpose of this study to compare measurements of R and Qac obtained by two different techniques which are based on the same principle of indicator dilution, but which differ because of the characteristics of the injection and detection of the d...
متن کاملVariable pump flow-based Doppler ultrasound method: a novel approach to the measurement of access flow in hemodialysis patients.
Decreasing vascular access flow (Qa) is an important predictor of future access thrombosis and malfunction for hemodialysis (HD) patients. Among all of the methods for determining Qa, the variable pump flow (VPF) Doppler method measures Qa according to the change in Doppler signal between the arterial and the venous needles under different pump flow. After this technique was combined with spect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Society of Nephrology : JASN
دوره 7 6 شماره
صفحات -
تاریخ انتشار 1996