Potentiometric adenosine triphosphate polyanion sensor using a lipophilic macrocyclic polyamine liquid membrane.

نویسندگان

  • Y Umezawa
  • M Kataoka
  • W Takami
  • E Kimura
  • T Koike
  • H Nada
چکیده

Interior/Geological Survey through Grant 14-080001-Gl441, administered through the North Dakota Water Resources Research Institute as Project No. 6582 (D.E.T.), and by the National Science Foundation, Grants fJHE-g411000 (R.C.E.) and CHE-8711595 (D.E.T.). A portion of this work was performed a t the Regional Instrumentation Facility for Surface Science, originally funded by the National Science Foundation under Grant CHE-7916206. RECEIVED for review February 8,1988. Accepted July 11,1988. This work was supported by the U.S. Department of the

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Determination of High Charge Density Polyanion Contaminants in Biomedical Heparin Preparations Using Potentiometric Polyanion Sensors.

Quantification of oversulfated chondroitin sulfate (OSCS) in biomedical heparin preparations is achieved using a recently described potentiometric polyanion sensor-based approach operated in a kinetic mode of analysis. This is accomplished by adjusting the concentration of the test sample to a range where the OSCS level is low enough for the sensor not to achieve a full and rapid equilibrium ph...

متن کامل

Application of a New Macrocyclic -PVC Electrode to Potentiometric Studies of Fe(III) Ion

A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....

متن کامل

Glyphosate and ATP binding by mononuclear Zn(II) complexes with non-symmetric ditopic polyamine ligands.

Binding of Zn(II) by the ditopic ligands L1py, L2py and L1para, composed of a cyclam unit linked to the linear polyamines 1,4,8,11-tetraazaundecane (L1py and L2para) and 1,4,7-triazaheptane (L2py) via a 2,6-dimethylpyridinyl (L1py and L2py) or a 1,4-dimethylbenzyl spacer (L2para), has been analyzed by means of potentiometric and (1)H and (13)C NMR measurements. All ligands form stable mononucle...

متن کامل

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 60 21  شماره 

صفحات  -

تاریخ انتشار 1988