Separation and characterization of octylphenol ethoxylate surfactants used by reversed-phase high-performance liquid chromatography on branched fluorinated silica gel columns.

نویسندگان

  • T Kamiusuki
  • T Monde
  • F Nemoto
  • T Konakahara
  • Y Takahashi
چکیده

The separation and characterization of octylphenol ethoxylate surfactants were carried out by reversed-phase high-performance liquid chromatography on branched fluorinated silica gel columns. For Triton X-100, simultaneous separation of octylphenol ethoxylate oligomers, positional isomers of octylphenyl group and butylphenol ethoxylate oligomers was achieved. These oligomers were completely separated and identified by means of MS spectra. Ethoxylated oligomers are eluted in the sequence from small to large oligomers. Fifty-five oligomers of Triton X-405 could be separated by using gradient elution. To separate octylphenol ethoxylate surfactant, non-end-capped branched fluorinated silica gel columns were superior to end-capped columns. The relationship between ln k' and methanol concentration was linear, indicating that branched fluorinated silica gel columns were operating in the reversed-phase mode. As Van 't Hoff plots of capacity factor for all oligomers gave straight lines, the equilibrium of conformation for the ethylene oxide chain might lay to one side of either zigzag or meander conformers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study of polyethoxylated alkylphenols by packed column supercritical fluid chromatography.

Alkylphenol polyethoxylates (APEs) are a widely used group of nonionic surfactants in commercial production. Characterization of the composition of APE mixtures can be exploited for the determination of their most effective uses. In this study sample mixtures contain nonylphenol polyethoxylates and octylphenol polyethoxylates. The separation of individual alkylphenols by ethoxylate units is per...

متن کامل

Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

Abstract Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic,anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported . Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used ...

متن کامل

Quantitative Determination of LPG Hydrocarbons by Modified Packed Column Adsorbent of Gas Chromatography Via Full Factorial Design

In this study, a new silica gel based adsorbent was fabricated and its ability in separation and quantification of alkanes mixture was investigated. Silica gel (SiO2) is a polar absorbent which is mainly used to separate polar compounds. Also, the carbon materials such as activated carbon and recently carbon nanotube (CNTs), have been widely used for separation of nonpolar materials. Carbon nan...

متن کامل

Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

Abstract Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic,anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported . Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used ...

متن کامل

SEPARATION OF NONHISTONE HIGH MOBILITY GROUP (HMG) FROM HUMAN LYMPHOCYTES BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

The high mobility group (HMG) of nonhistone proteins have been investigated using two high performance liquid chromatographic techniques (HPLC). Reversed-phase HPLC under conditions of 50 mM triethylamine adjusted to pH 2.2 with phosphoric acid (solvent A) and 95% acetonitrile in water (solvent B) was used to separate proteins primarily on the basis of differences in the overall hydrophobi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 852 2  شماره 

صفحات  -

تاریخ انتشار 1999