Comparison of 3 Derivatization Methods for the Analysis of Amphetamine-Related Drugs in Oral Fluid by Gas Chromatography-Mass Spectrometry

نویسندگان

  • Khaled M Mohamed
  • Abdulsallam Bakdash
چکیده

The heptafluorobutyric anhydride (HFBA), pentafluoropropionic anhydride (PFPA), and trifluoroacetic anhydride (TFAA) are compared as derivatizing reagents to use as the optimal method for the analysis of 10 amphetamines and cathinones in oral fluid. The target compounds were amphetamine (AMP), methamphetamine (MA), 4-methylamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA), cathinone (CAT), methcathinone, mephedrone, and ephedrine. Amphetamine-D5, MA-D5, MDA-D5, MDMA-D5, and MDEA-D5 use as internal standards (IS). The analytes and IS were extracted from 0.5 mL of oral fluid by ethyl acetate in the presence of NaOH (0.1 N) as the base and then the dried extracts were derivatized with HFBA, PFPA, or TFAA at 70°C for 30 minutes. The limits of quantification based on signal-to-noise ratios ≥10 were ranged between 2.5 and 10 ng/mL. The calibration graphs were linear in the range of 5 or 10 to 1000 ng/mL for all analytes. Based on sensitivity, the PFPA is proved to be the best for derivatization of the target compounds prior to gas chromatography-mass spectrometry analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تشخیص مواد شیمیایی در اثر انگشت بوسیله تکنیک دستگاهی کروماتوگرافی گازی/اسپکترومتری جرمی

Objective: It has been greatly attempted to learn more about chemical information on finger prints using new vehicular technique use for the detection of a variety of substances, including narcotic drugs and medicines, as well using nano particles bound to specific antibodies. Over the last few years, the sensitive techniques of gas chromatography and mass spectrometry have been found for the d...

متن کامل

Validation of the Cozart Amphetamine Microplate EIA for the analysis of amphetamines in oral fluid.

The purpose of this study was to determine the performance characteristics of the Cozart Amphetamine Microplate EIA for detecting amphetamine in oral fluid. Oral fluid samples were collected using the Cozart RapiScan Collection System from 135 volunteer donors from drug treatment clinics. A further 35 oral fluid samples were collected from volunteer donors who were not drug users. The samples w...

متن کامل

Automated headspace solid-phase microextraction and in-matrix derivatization for the determination of amphetamine-related drugs in human urine by gas chromatography-mass spectrometry.

An automated extraction and determination method for the gas chromatography (GC)-mass spectrometry (MS) analysis of amphetamine-related drugs in human urine is developed using headspace solid-phase microextraction (SPME) and in-matrix derivatization. A urine sample (0.5 mL, potassium carbonate (5 M, 1.0 mL), sodium chloride (0.5 g), and ethylchloroformate (20 microL) are put in a sample vial. A...

متن کامل

A microwave-assisted fluorescent labeling method for the separation and detection of amphetamine-like designer drugs by capillary electrophoresis.

A microwave-assisted fluorescence labeling method for use in CE-LIF (capillary electrophoresis-laser induced fluorescence) is described. Six amphetamine-like designer drugs, namely, o-, m-, p-chloro- and o-, m-, p-fluoro-amphetamine derivatives, were synthesized and used as model compounds. FITC (fluorescein isothiocyanate isomer I) and a blue-laser were used as the fluorescent labeling reagent...

متن کامل

Drug testing in oral fluid-evaluation of sample collection devices.

Nine different oral fluid (OF) collection devices were studied to evaluate their suitability for collecting samples for drug analysis. The devices were Greiner Bio-One, Orasure Intercept, Immunalysis Quantisal, StatSure Saliva.Sampler, Cozart, Sarstedt Salivette, Malvern Medical OraCol, Acro Biotech Salicule, and Varian OraTube. For comparison, OF was also collected into plastic tubes. The volu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017