Combination method of bone-conduction speech and air-conduction speech for speaker recognition

نویسندگان

  • Satoru Tsuge
  • Takashi Osanai
  • Hisanori Makinae
  • Toshiaki Kamada
  • Minoru Fukumi
  • Shingo Kuroiwa
چکیده

Recently, some new sensors, such as bone-conductive microphones, throat microphones, and non-audible murmur (NAM) microphones, besides conventional condenser microphones have been developed for collecting speech data. Accordingly, some researchers began to study speaker and speech recognition using speech data collected by these new sensors. We focus on bone-conduction speech data collected by the bone-conductive microphone. This paper proposes a novel speaker identification method which combines “bone-conduction speech” and “airconduction speech”. The proposed method conducts speaker identification by integrating the similarity calculated by airconduction speech model and similarity calculated by boneconduction speech model. For evaluating the proposed method, we conduct the speaker identification experiment using part of a large bone-conduction speech corpus constructed by National Research Institute of Police Science, Japan (NRIPS). Experimental results show that the proposed method can reduce a identification error rate of air-conduction speech and boneconduction speech. Especially, the proposed method achieves that the average error reduction rate from air-conduction speech to the proposed method is 35.8%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Fluoroplastic Causse Loop Piston and Titanium Soft-Clip in Stapedotomy

Introduction:Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis.Materials and Methods:A total of 57 ears were included in ...

متن کامل

Intraindividual comparison of the bone-anchored hearing aid and air-conduction hearing aids.

BACKGROUND Some patients have to stop using their air-conduction hearing aid(s) because it causes or exacerbates chronic otitis. Then, a solution is the use of a bone-conduction hearing aid such as the percutaneous bone-anchored hearing aid (BAHA). OBJECTIVE To compare patients' performance with their previous air-conduction hearing aid(s) and their BAHA using audiometric tests and a question...

متن کامل

The effect of sensorineural hearing loss and tinnitus on speech recognition over air and bone conduction military communications headsets

Military personnel are at risk for hearing loss due to noise exposure during deployment (USACHPPM, 2008). Despite mandated use of hearing protection, hearing loss and tinnitus are prevalent due to reluctance to use hearing protection. Bone conduction headsets can offer good speech intelligibility for normal hearing (NH) listeners while allowing the ears to remain open in quiet environments and ...

متن کامل

تغییرات هدایت استخوانی پس از بازسازی زنجیره استخوانچه‌ای گوش میانی

    Background & Aim: The most common surgically treatable causes of hearing loss are middle ear diseases among which the greatest effect is related to ossicular chain dysfunction. Successful ossicular chain reconstruction certainly improves air conduction thresholds and closes air-bone gap in audiograms, but the effect of this procedure on bone conduction thresholds has remained to be elucidat...

متن کامل

Intelligibility of bone-conducted speech at different locations compared to air-conducted speech

Bone-conduction transducers offer a unique advantage for radio communication systems, allowing sound transmission while the ear canals remain open for access to environmental sounds, or plugged for blocking of environmental sounds. This study compared the intelligibility of noise-degraded speech presented through bone-conduction hearing administered at different locations, and through air-condu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008