A continuous quality improvement project to decrease hemodialysis catheter infections in pediatric patients: use of a closed luer-lock access cap.

نویسندگان

  • Nancy McAfee
  • Kristy Seidel
  • Sandra Watkins
  • Joseph T Flynn
چکیده

Catheter infections are a significant problem in pediatric hemodialysis. To reduce infection rates, the use of closed luer-lock access connectors, which create a mechanically and microbiogically closed system while allowing unobstructed blood flow, was implemented Infection rates fell from 7.8 infections per 1000 patient days to 3.65 infections per 1000 patient days after the switch to the closed connector (t = 0.04). The adoption of a closed connector system appeared to produce a significant reduction in bloodstream infections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk of infection due to medical interventions via central venous catheters or implantable venous access port systems at the middle port of a three-way cock: luer lock cap vs. luer access split septum system (Q-Syte)

BACKGROUND Many cancer patients receive a central venous catheter or port system prior to therapy to assure correct drug administration. Even appropriate hygienic intervention maintenance carries the risk of contaminating the middle port (C-port) of a three-way cock (TWC), a risk that increases with the number of medical interventions. Because of the complexity of the cleaning procedure with di...

متن کامل

اثر بلوک هپارین-آنتی بیوتیک بر پیشگیری از عفونت کاتترهای دولومینه در بیماران همودیالیزی: یک مطالعه کارآزمایی بالینی

Background and purpose: One of the most common complications of catheter in hemodialysis patients is infections and many methods have been proposed to prevent it. This study compared the effects of heparin lock-antibiotics and heparin to prevent infections in patients undergoing hemodialysis. Materials and methods: This single blind clinical trial included 122 patients who were randomly assign...

متن کامل

The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections

Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...

متن کامل

Is Taurolidine-citrate an effective and cost-effective hemodialysis cathe-ter lock solution? A systematic review and cost- effectiveness analysis

Background: Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other ...

متن کامل

How much is red blood cell fragmentation increased by the use of closed luer lock access devices on catheter hubs?

The opening and manipulation of central venous (CV) catheters before and after each dialysis event might result in catheter-related blood stream infections [1–3]. In order to reduce those infection risks, different types of closed luer lock access devices are commercially available. Such connectors are placed on the arterial and venous catheter hub and are designed with a split septum of medica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology nursing journal : journal of the American Nephrology Nurses' Association

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 2010