Cyclic fatigue testing of three different rotary nickel titanium endodontic instruments in simulated curved canals - an in vitro sem analysis.

نویسندگان

  • Pallavi Reddy Y
  • Kavita S
  • C V Subbarao
چکیده

INTRODUCTION Instrument separation is a serious concern in endodontics. Stainless steel instruments usually deform before they separate whereas Nickel Titanium instruments do not show any sign of deformation. AIM of the present study was to compare the cyclic rotations needed to fracture three different rotary nickel titanium endodontic instruments namely Profile, K3 Endo, RaCe in simulated curved canals having 2 different radii of curvature i.e., 5mm &10mm with a constant angle of curvature of 45°. The fractured surfaces were analysed using Scanning Electron Microscopy (SEM). MATERIALS AND METHODS Sixty rotary nickel titanium instruments were used for analysis in this study. The instruments were divided into three groups based on the different cross sections. Three groups were further divided into two sub groups based on radius of curvatures. Ten files were tested in each sub-group. RESULTS Group A (Profile) showed increased number of cycles to failure i.e., low incidence of fracture at both the radii of curvatures when compared to the other two groups. SEM analysis showed that in Group A the fractured surface of the files tested were characterized by the presence of smooth area on their edges associated with nucleation and slow fatigue crack propagation when compared to Group B and C. Therefore Group A (Profile) demonstrated least cyclic fatigue when compared to the other two groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems.

AIM To determine how instrument design affects the fatigue life of two nickel-titanium (Ni-Ti) rotary systems (Mtwo and ProTaper) under cyclic fatigue stress in simulated root canals. METHODOLOGY Cyclic fatigue testing of instruments was performed in stainless steel artificial canals with radii of curvature of 2 or 5 mm and an angle of curvature of 60 degrees . A total of 260 instruments were...

متن کامل

Torsion Property and Cyclic Fatigue Fracture Behavior of Nickel-Titanium Endodontic Instruments

The torsion property and rotary fatigue fracture behavior of Smart K file and R reamer made of nickel titanium alloy have been studied by means of Shimadzu Autograph DDS-10T universal tester and man-made cyclic system with curved copper tubes as simulated root canal. The instrument surface and the cyclic fatigue fracture surface have been investigated by optical microscope and scanning electro...

متن کامل

Cyclic Fatigue of Different Nickel-Titanium Rotary Instruments: A Comparative Study

Since the introduction of nickel-titanium alloy to endodontics, there have been many changes in instrument design, but no significant improvements in the raw material properties, or enhancements in the manufacturing process. Recently, a new method to produce nickel-titanium rotary (NTR) instruments has been developed, in an attempt to obtain instruments that are more flexible and resistant to f...

متن کامل

Cyclic fatigue resistance of rotary NiTi instruments after simulated clinical use in curved root canals.

The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments after simulated clinical use in curved root canals (40-degree, 5-mm radius curve). Thirty-six RaCe rotary NiTi files, size #5, taper 0.04, were divided into 3 groups: Groups A, B and C with one, three and five cycles of use, respectively. Time to failure was recorded with a stopwatch in seconds a...

متن کامل

Fracture resistance of electropolished rotary nickel-titanium endodontic instruments.

The purpose of this study was to investigate the effect of electropolishing on cyclic flexural fatigue and torsional strength of rotary nickel-titanium endodontic instruments. Electropolished and nonelectropolished ISO size 30 (0.04 taper) EndoWave (J Morita Corporation, Osaka, Japan), ProFile (Dentsply Maillefer, Ballaigues, Switzerland), and RaCe (FKG, La-Chaux De Fonds, Switzerland) instrume...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical and diagnostic research : JCDR

دوره 8 2  شماره 

صفحات  -

تاریخ انتشار 2014