Intraocular Pressure Reduction Is Associated with Reduced Venous Pulsation Pressure

نویسندگان

  • William H. Morgan
  • Philip H. House
  • Martin L. Hazelton
  • Brigid D. Betz-Stablein
  • Balwantray C. Chauhan
  • Ananth Viswanathan
  • Dao-Yi Yu
  • Sanjoy Bhattacharya
چکیده

PURPOSE To explore whether alterations in intraocular pressure (IOP) affect vein pulsation properties using ophthalmodynamometric measures of vein pulsation pressure. PATIENTS AND METHODS Glaucoma patients had two retinal vein pulsation pressure (VPP) measurements from upper and lower hemiveins performed by ophthalmodynamometry at least 3 months apart. All subjects had VPP and IOP recorded at two visits, with standard automated perimetry, central corneal thickness (CCT) recorded at the initial visit. Where venous pulsation was spontaneous ophthalmodynamometry could not be performed and VPP was considered equal to IOP. Change in VPP was calculated and binarized with reduction in pressure scored 1 and no change or increase scored as 0. Data analysis used a mixed logistic regression model with change in VPP as response variable and change in IOP, visual field loss (mean deviation), CCT and time interval as explanatory variables. RESULTS 31 subjects (20 females) with mean age 60 years (sd 11) were examined with change in VPP being significantly associated with change in IOP (odds ratio 1.6/mmHg, 95% CI 1.2 to 2.1 in the glaucoma patients but not suspect patients (p = 0.0005). CONCLUSION Change in VPP is strongly associated with change in IOP such that a reduced intraocular pressure is associated with a subsequent reduction in VPP. This indicates that reduced IOP alters some retinal vein properties however the nature and time course of these changes is not known.

منابع مشابه

Spontaneous retinal venous pulsation: aetiology and significance.

Spontaneous retinal venous pulsation is seen as a subtle variation in the calibre of the retinal vein(s) as they cross the optic disc. The physical principles behind the venous pulsations has been the point of much debate. Initial theories suggested that the pulsation occurred because of the rise in intraocular pressure in the eye with the pulse pressure. This article presents an argument that ...

متن کامل

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

New observations concerning the nature of central retinal vein pulsation.

AIMS Central retinal vein pulsation is affected by intracranial pressure (ICP), glaucoma and venous pathology. Its genesis is poorly understood with most models suggesting that intraocular pressure (IOP) fluctuation dominates the rhythm of venous pulsation; however, this has not been explored experimentally. This study planned to measure the timing of central retinal vein pulsation with respect...

متن کامل

Circulatory Studies of the Fundus of the Eye.

OUR investigations assumed first that the difference of pressure between the arterial and venous parts of the capillary system acts as circulatory motor, further, that spontaneous venous pulsation of the fundus of the eye is a sign of a pressure prevailing within the central retinal vein lower than the intra-ocular tension. One hundred cases were examined: fifty of them showing spontaneous puls...

متن کامل

Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects

Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016