A Generic Method of Line Matching for Central Imaging Systems under Short-Baseline Motion

نویسندگان

  • Saleh Mosaddegh
  • David Fofi
  • Pascal Vasseur
چکیده

Line matching across images taken by a central imaging system (perspective or catadioptric) with focus on short baseline motion of the system is proposed. The relationship between images of lines on unitary sphere is studied and a simple algorithm for matching lines are proposed assuming the rotation of the system is known apriori or it can be estimated from some correspondences in two views. Two methods are discussed for retrieving R in the case it is not known apriori. Experimental results on both synthetic and real images are also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two View Line-Based Matching, Motion Estimation and Reconstruction for Central Imaging Systems

The primary goal of this thesis is to develop generic motion and structure algorithms for images taken from constructed scenes by various types of central imaging systems including perspective, fish-eye and catadioptric systems. Assuming that the mapping between the image pixels and their 3D rays in space is known, instead of image planes, we work on image spheres (projection of the images on a...

متن کامل

Line Matching across Catadioptric Images under Short-Baseline Motion

Line matching across catadioptric images using line intersections with focus on short baseline motion of the imaging system is proposed. The relationship between images of constructing lines of an intersection on unitary sphere is studied and angle consistency and antipodal consistency are introduced as two useful properties which can be employed to nd putative intersections correspondence and ...

متن کامل

Fibro Osseous Lesions – Classifications, Pathophysiology and Importance of Radiology: a Short Review

Fibro osseous lesions (FOLs) are a generic designation of poorly defined group of lesions which are recognized to affect the jaws and the craniofacial bones which are known for their confusing area in diagnostic pathology. The disease comprises of varied processes in which the normal architecture of bone is replaced by fibrous tissue containing varying amount of foci of mineralization. Regardle...

متن کامل

Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)

Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...

متن کامل

On Motion Estimation and Compensation Baseline Estimations in Dynamic Imaging: a Comparative Study with Cine Cardiac and Contrast-Enhanced Lung Imaging

Introduction: Estimation of the baseline in a dynamic imaging series is an essential step in compressed-sensing-based acceleration methods for MRI acquisition [1,2], as an accurate baseline estimation helps sparsifying the remaining residues effectively. Recent literatures suggest improved baseline estimation using adaptive regularization [1] or motion estimation (ME) and motion compensation (M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009