There Is No Safe Dose of Prions

نویسندگان

  • Helen R. Fryer
  • Angela R. McLean
چکیده

Understanding the circumstances under which exposure to transmissible spongiform encephalopathies (TSEs) leads to infection is important for managing risks to public health. Based upon ideas in toxicology and radiology, it is plausible that exposure to harmful agents, including TSEs, is completely safe if the dose is low enough. However, the existence of a threshold, below which infection probability is zero has never been demonstrated experimentally. Here we explore this question by combining data and mathematical models that describe scrapie infections in mice following experimental challenge over a broad range of doses. We analyse data from 4338 mice inoculated at doses ranging over ten orders of magnitude. These data are compared to results from a within-host model in which prions accumulate according to a stochastic birth-death process. Crucially, this model assumes no threshold on the dose required for infection. Our data reveal that infection is possible at the very low dose of a 1000 fold dilution of the dose that infects half the challenged animals (ID50). Furthermore, the dose response curve closely matches that predicted by the model. These findings imply that there is no safe dose of prions and that assessments of the risk from low dose exposure are right to assume a linear relationship between dose and probability of infection. We also refine two common perceptions about TSE incubation periods: that their mean values decrease linearly with logarithmic decreases in dose and that they are highly reproducible between hosts. The model and data both show that the linear decrease in incubation period holds only for doses above the ID50. Furthermore, variability in incubation periods is greater than predicted by the model, not smaller. This result poses new questions about the sources of variability in prion incubation periods. It also provides insight into the limitations of the incubation period assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Dose Psoralen Plus Ultraviolet A (PUVA) Is an Effective and Safe Method for the Treatment of Chronic Graft Versus Host Disease

Background: Chronic graft versus host disease (ch.GVHD) is the most frequent late complication after allogenic stem-cell transplantation. Systemic immunosuppressive agents are usually required to control the disease. Psoralen plus UVA (PUVA) has been used for the treatment of ch.GVHD with variable beneficial effects. The objective of this study was to assess the efficacy and safety of a r...

متن کامل

Low dose Methotrexate for the treatment of generalized lichen planus

Background: Lichen planus is a common inflammatory disease that can involve the skin, nails, mucous membrane, and hair follicles. There is a long list of topical and systemic therapies for its treatment. Methotrexarte has some characteristics that make it a good choice for generalized lichen planus. Aim: The goal of this study was to assess the effect of low dose methotrexate in generalized lic...

متن کامل

Fomepizole as a First-line Treatment of Patients with Methanol Poisoning

Methanol is responsible for a life-threatening poisoning. Fomepizole, a potent alcohol dehydrogenase inhibitor, is an efficient and safe antidote that prevents or reduces toxic methanol metabolism. Although no study has compared its efficacy with ethanol, fomepizole is recommended as a first-line antidote. Treatment should be started as soon as possible, based on history and initial findings in...

متن کامل

Is Daycare Tonsillectomy Safe?

Introduction: Tonsillectomy is one of the most common procedures performed by Ear, Nose, and Throat surgeon.  Usually, the procedure is carried out as an inpatient surgery. With the increasing need to reduce healthcare costs, spare precious hospital beds, and shorten elective surgery lists, there is currently a trend towards performing tonsillectomy on a daycare basis.  Materials and Methods: A...

متن کامل

Simulation of environmental dose distribution of nuclear gauge device MC-1DR by MCNPX code

In this study, distribution of dose rate around the nuclear gauge device MC-1DR which located in shahrekord university was simulated by MCNPX code and was compared whit the measured values. Due to the asymmetry of device and neutron and gamma source positions, the dose rates were determined at a distance of 5, 30 and 100 cm in different directions. Base on the complex geometry of the inside of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011