Accuracy of linear and angular measurements on panoramic radiographs taken at various positions in vitro.

نویسندگان

  • Steve Stramotas
  • Joseph P Geenty
  • Peter Petocz
  • M Ali Darendeliler
چکیده

The accuracy of measurement of tooth length and angulation on dental panoramic tomograms (DPTs) is thought to be highly dependent on head positioning technique. A model representing the dentition and the functional occlusal plane was designed using an acrylic framework and stainless steel wires. The aim was to investigate whether varying the position of the model affects the linear and angular measurements on DPTs. Four different positions were investigated: initial position representing natural head posture (NHP) (T1); lateral right cant of the occlusal plane (T2); lateral left cant of the occlusal plane (T3); and tilting the occlusal plane up anteriorly (T4). On each DPT, four sets of measurements were recorded: (1) Vertical linear measurements of the stainless steel pins and ratio calculations of the 'crown' and 'root' segments (represented by the wire above and below the occlusal plane, respectively); (2) angular measurements of the pins relative to the occlusal plane; (3) angular measurements of the pins relative to a constructed reference line; and (4) angular measurements of pins relative to each other in the same segment. The results showed a significant error (P < 0.05) in all measurements when the occlusal plane was tilted up anteriorly by 8 degrees. A lateral cant of the occlusal plane by less than 10 degrees without an upward anterior rotation showed no significant effect on the measurements. This would suggest that there is some tolerance of variation in head position.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions

PURPOSE This study assessed the accuracy of linear and angular measurements on panoramic radiographs taken at different positions in vitro. MATERIALS AND METHODS Two acrylic models were fabricated from a cast with normal occlusion. Straight and 75° mesially and lingually angulated pins were placed, and standardized panoramic radiographs were taken at standard position, at an 8° downward tilt ...

متن کامل

دقت رادیوگرافی پانورامیک و توموگرافی خطی در تعیین محل کانال مندیبولار

Background and Aim: Accurate bone measurements are essential to determine the optimal size and length of dental implants. The magnification factor of radiographic images may vary with the imaging technique used. The purpose of this study was to compare the accuracy of linear tomography and panoramic radiography in vertical measurements, as well as the accuracy of linear tomography in mandibular...

متن کامل

Effect of Head Misalignment in Horizontal & Vertical Dimensions on the Magnification Rate of Digital Panoramic Radiography in Different Parts of the Jaws

Background and aim: Considering the widespread development of implants in dental treatment plans, linear measurements on panoramic radiography are of especial importance. In the present study we investigated the effect of head misalignment up to 15&deg; around vertical and horizontal axes on the magnification rate of digital panoramic radiography in each part of upper and lower jaws. Materia...

متن کامل

بررسی و مقایسه دقت رادیوگرافی های پانورامیک، پری اپیکال و بایت وینگ در تعیین میزان تحلیل استخوان آلوئول در پریودنتیت

Introduction: The height of the alveolar bone, is normally maintained by equilibrium between bone formation and bone resorption, but in periodontal disease more destruction or lack of bone formation will reduce the alveolar bone height. However the radiography is important in diagnosis, treatment plan and detection of quality and quantity of the alveolar bone although the type of radiography is...

متن کامل

بررسی توانایی رادیوگرافی پانورامیک برای ارتباط دادن بعد عرضی و ساژیتال در افراد اسکلتال کلاس III

Background and Aims: In the field of orthodontics, gaining comprehensive information around dento-skeletal complex is necessary to choose the best treatment plan for each patient. The aim of this study was to investigate the linear and angular parameters in panoramic radiographs to find a path to correlate transvers to sagittal dimensions. Materials and Methods: Total number of sixty two, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2002