Evaluation of Fixation Disparity Curve Parameters With the Modified Near Mallett Unit in Symptomatic and Asymptomatic University Students
نویسندگان
چکیده
BACKGROUND Research suggests that fixation disparity data are extremely useful in the assessment of the binocular and accommodative systems. OBJECTIVES The purpose of this study was to evaluate fixation disparity curve (FDC) parameters with a modified near Mallett unit in symptomatic and asymptomatic students of Paramedical Sciences School of Mashhad University of Medical Sciences in 2007. PATIENTS AND METHODS In this analytical-descriptive study, 100 students were selected randomly and divided into symptomatic and asymptomatic groups. Fixation disparity curve parameters were determined for each subject and compared in symptomatic and asymptomatic groups. RESULTS There were more subjects with exo fixation disparity than eso fixation disparity in the study sample. The means for fixation disparity, fixation disparity curve x-intercept, and slope with the modified Mallett unit were each significantly different by Mann-Whitney U test in the symptomatic and asymptomatic groups. Also there was a significant difference in the distributions of fixation disparity curve types in the two symptom groups by Chi-square test. CONCLUSIONS The X-intercepts (point at which the FDC crosses the X-axis) were on average more in the base-in direction, Y-intercepts (point at which the FDC crosses the Y-axis) were shifted in the exo direction, and slopes were steeper in the symptomatic group.
منابع مشابه
The Mallett Fixation Disparity Test: influence of test instructions and relationship with symptoms.
Fixation disparity is a minute ocular misalignment under conditions of binocular single vision and is typically detected in primary eye care practices in the UK using the Mallett Unit Fixation Disparity Test. This instrument creates natural viewing conditions, when the patient's binocular system is fused using both central and peripheral fusion locks. This allows the examiner to determine the m...
متن کاملThe effect of induced visual stress on three dimensional perception.
Previous studies have shown that stress on the vergence and accommodation systems, either artificially induced or naturally occurring, results in small misalignment of the visual axes, reduces binocular visual acuity and produces symptoms of ocular discomfort. This study examines the effect of artificially induced visual stress using ophthalmic prisms on three dimensional perception on 30 optom...
متن کاملIs the Aligning Prism Measured with the Mallett Unit Correlated with Fusional Vergence Reserves?
BACKGROUND The Mallett Unit is a clinical test designed to detect the fixation disparity that is most likely to occur in the presence of a decompensated heterophoria. It measures the associated phoria, which is the "aligning prism" needed to nullify the subjective disparity. The technique has gained widespread acceptance within professions such as optometry, for investigating suspected cases of...
متن کاملThe role of the optometrist in dyslexia
would be present when the patient is reading. The test therefore has good ‘face validity’ for identifying binocular vision anomalies which are likely to interfere with the usual reading process. Recent research has shown that the questions the practitioner asks during this test are crucially important. Quite commonly, the patient is just asked whether the Nonius markers (green strips) are lined...
متن کاملStereopsis with TNO and Titmus Tests in Symptomatic and Asymptomatic University Students
Journal of Behavioral Optometry Abstract Introduction: One factor in the evaluation of binocular vision is the measurement of stereopsis. Several methods are available for this purpose. The most common procedures are anaglyphic (with use of red-green filters) and vectographic (with use of polarized filters) procedures. The purpose of this study is the determination of stereopsis with local (Tit...
متن کامل