Echo time optimization for linear combination myelin imaging.

نویسندگان

  • Logi Vidarsson
  • Steven M Conolly
  • Kelvin O Lim
  • Garry E Gold
  • John M Pauly
چکیده

A 3-echo linear combination myelin imaging method is presented. The echo times and weights are chosen such that the signal-to-noise ratio (SNR) of myelin-water is maximized, and signals from other white matter components are sufficiently suppressed. Interfering tissue water and cerebrospinal fluid (CSF) signals are much stronger than myelin due to their longer T2 and abundance. By carefully optimizing the echo times a 50-fold tissue water suppression is achieved along with a 10-fold CSF suppression. For comparison 4, 5, and 32 echo filters are also designed using the same method. The SNR efficiency of these filters is very similar. The 3-echo filter design was validated by phantom scans. In addition, multislice in vivo myelin images were acquired from both a healthy volunteer and a multiple sclerosis patient. Total scan time was 5 min. A uniform T2 filter is also designed to pass all white matter species with uniform gain. The myelin-water fraction of the in vivo 3-echo data set is then measured by dividing the myelin image by the uniformly filtered image. Obtained myelin-water fractions compare well with previous work.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

متن کامل

Compressed sensing CPMG with group-sparse reconstruction for myelin water imaging.

PURPOSE Myelin content is a marker for nervous system pathology and is quantifiable by myelin water imaging using multi-echo CPMG sequence, which is inherently slow. One way to accelerate the scan is to utilize compressed sensing. However, reconstructing the images piecemeal by standard compressed sensing methods is not the optimal solution, because it only exploits intraimage spatial redundanc...

متن کامل

Sex differences in the human corpus callosum microstructure: T2 myelin-water imaging versus diffusion tensor imaging

Introduction: The corpus callosum (CC) plays an important role in relaying sensory, motor and cognitive function between the cerebral hemispheres. Females seem to employ a greater degree of bilateral hemispheric activity than males (1) and also have a larger callosal area in proportion to brain volume (2) which suggests that a larger number of fibres are passing through. We have previously show...

متن کامل

Untangling the R2* contrast in multiple sclerosis: A combined MRI-histology study at 7.0 Tesla

T2*-weighted multi-echo gradient-echo magnetic resonance imaging and its reciprocal R2* are used in brain imaging due to their sensitivity to iron content. In patients with multiple sclerosis who display pathological alterations in iron and myelin contents, the use of R2* may offer a unique way to untangle mechanisms of disease. Coronal slices from 8 brains of deceased multiple sclerosis patien...

متن کامل

In Vivo Myelin Water Imaging Using 3d Multi-gradient-echo Pulse Sequences

Introduction. Quantitative imaging of the myelin water fraction (MWF) is able to show demyelinating processes and therefore provides insight into the pathology of white matter (WM) diseases such as multiple sclerosis. So far, mapping of the MWF most often was performed using single-slice multi-echo spin-echo sequences (1). Lately, a different approach, using multi-gradient-echo pulse sequences,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 53 2  شماره 

صفحات  -

تاریخ انتشار 2005