Feasibility of using nonflat photon beams for whole‐breast irradiation with breath hold

نویسندگان

  • Yuenan Wang
  • Andrew Vassil
  • Rahul Tendulkar
  • John Bayouth
  • Ping Xia
چکیده

Removing a flattening filter or replacing it with a thinner filter alters the characteristics of a photon beam, creating a forward peaked intensity profile to make the photon beam nonflat. This study is to investigate the feasibility of applying nonflat photon beams to the whole-breast irradiation with breath holds for a potential of delivery time reduction during the gated treatment. Photon beams of 6 MV with flat and nonflat intensity profiles were commissioned. Fifteen patients with early-stage breast cancer, who received whole-breast radiation without breathing control, were retrospectively selected for this study. For each patient, three plans were created using a commercial treatment planning system: (a) the clinically approved plan using forward planning method (FP); (b) a hybrid intensity-modulated radiation therapy (IMRT) plan where the flat beam open fields were combined with the nonflat beam IMRT fields using direct aperture optimization method (mixed DAO); (c) a hybrid IMRT plan where both open and IMRT fields were from nonflat beams using direct aperture optimization (nonflat DAO). All plans were prescribed for ≥ 95% of the breast volume receiving the prescription dose of 50 Gy (2.0 Gy per fraction). In comparison, all plans achieved a similar dosimetric coverage to the targeted volume. The average homogeneity index of the FP, mixed DAO, and nonflat DAO plans were 0.882 ± 0.024, 0.879 ± 0.023, and 0.867 ± 0.027, respectively. The average percentage volume of V105 was 57.66% ± 5.21%, 34.67% ± 4.91%, 41.64% ± 5.32% for the FP, mixed, and nonflat DAO plans, respectively. There was no significant difference (p > 0.05) observed for the defined endpoint doses in organs at risk (OARs). In conclusion, both mixed DAO and nonflat DAO plans can achieve similar plan quality as the clinically approved FP plan, measured by plan homogeneity and endpoint doses to the ORAs. Nonflat beam plans may reduce treatment time in breath-hold treatment, especially for hypofractionated treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of two radiation techniques in breast boost delivery

Introduction: In the treatment of breast cancer, breast conserving surgery (BCS) and whole breast irradiation is a usual technique. The influence of lumpectomy boost following breast radiotherapy is apparent, but there are different delivery methods. This work intended to compare the dosimetric parameters of electron beams and photon beams for boosting irradiation in breast can...

متن کامل

Dosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam

Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradia­tion in post‑lump...

متن کامل

Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

متن کامل

Reproducibility of deep inspiration breath hold for prone left-sided whole breast irradiation

BACKGROUND Investigating reproducibility and instability of deep inspiration breath hold (DIBH) in the prone position to reduce heart dose for left-sided whole breast irradiation. METHODS Thirty patients were included and underwent 2 prone DIBH CT-scans during simulation. Overlap indices were calculated for the ipsilateral breast, heart and lungs to evaluate the anatomical reproducibility of ...

متن کامل

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014