Comparison of transabdominal ultrasound and electromagnetic transponders for prostate localization

نویسندگان

  • Ryan D. Foster
  • Timothy D. Solberg
  • Haisen S. Li
  • Andrew Kerkhoff
  • Charles A. Enke
  • Twyla R. Willoughby
  • Patrick A. Kupelian
چکیده

The aim of this study is to compare two methodologies of prostate localization in a large cohort of patients. Daily prostate localization using B-mode ultrasound has been performed at the Nebraska Medical Center since 2000. More recently, a technology using electromagnetic transponders implanted within the prostate was introduced into our clinic (Calypso(R)). With each technology, patients were localized initially using skin marks. Localization error distributions were determined from offsets between the initial setup positions and those determined by ultrasound or Calypso. Ultrasound localization data was summarized from 16619 imaging sessions spanning 7 years; Calypso localization data consists of 1524 fractions in 41 prostate patients treated in the course of a clinical trial at five institutions and 640 localizations from the first 16 patients treated with our clinical system. Ultrasound and Calypso patients treated between March and September 2007 at the Nebraska Medical Center were analyzed and compared, allowing a single institutional comparison of the two technologies. In this group of patients, the isocenter determined by ultrasound-based localization is on average 5.3 mm posterior to that determined by Calypso, while the systematic and random errors and PTV margins calculated from the ultrasound localizations were 3 - 4 times smaller than those calculated from the Calypso localizations. Our study finds that there are systematic differences between Calypso and ultrasound for prostate localization.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of radiographic techniques and electromagnetic transponders for localization of the prostate

BACKGROUND The aim of this study is to compare three methodologies of prostate localization and to determine if there are significant differences in the techniques. METHODS Daily prostate localization using cone beam CT or orthogonal kV imaging has been performed at UT Southwestern Medical Center since 2006. Prostate patients are implanted with gold seeds, which are matched with the planning ...

متن کامل

Comparison of Transabdominal and Transrectal Ultrasonography of the Prostate Gland in Dogs

Objective- To compare transabdominal (TA) and transrectal (TR) ultrasonography of the prostate gland. Design- Experimental study. Animals- 10 intact male dogs that required euthanasia for reasons other than prostatic disease. Procedures- Prostatic length (L), width (W) and height (H) were measured in T A (L1, W1 and H1) and TR (L2 and H2...

متن کامل

Prostate tumor alignment and continuous, real-time adaptive radiation therapy using electromagnetic fiducials: clinical and cost-utility analyses.

OBJECTIVE To evaluate the accuracy, utility, and cost effectiveness of a new electromagnetic patient positioning and continuous, real-time monitoring system, which uses permanently implanted resonant transponders in the target (Calypso 4D Localization System and Beacon transponders, Seattle, WA) to continuously monitor tumor location and movement during external beam radiation therapy of the pr...

متن کامل

Application of Bland-Altman Method in Comparing Transrectal and Transabdominal Ultrasonography for Estimating Prostate Volume

Background: Estimating prostate volume using less invasive transabdominal ultrasonography (TAUS) instead of transrectal ultrasonography (TRUS) is of interest in terms of identifying their agreement level. Previous reports on this subject, applied general correlation coefficient as the level of agreement. This study uses Bland-Altman method to quantify TAUS and TRUS agreement on estimating prost...

متن کامل

AbstractID: 9182 Title: Automated Segmentation of the Prostrate from Transabdominal Ultrasound Images

ID: 9182 Title: Automated Segmentation of the Prostrate from Transabdominal Ultrasound Images We are investigating the accuracy with which a unique, semi-automatic segmentation process can outline the prostate on transabdominal ultrasound images. We anticipate that the fully developed method will increase the efficiency and reproducibility of radiation treatment planning and delivery, and may p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010