ACUT2E TSE-SSFP: a hybrid method for T2-weighted imaging of edema in the heart.
نویسندگان
چکیده
ACUT(2)E TSE-SSFP is a hybrid between steady state free precession (SSFP) and turbo spin echo (TSE) for bright-blood T2-weighted imaging with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) similar to dark-blood TSE. TSE-SSFP uses a segmented SSFP readout during diastole with 180 degrees pulses following a 90 degrees preparation. The 180 degrees refocusing pulses make TSE-SSFP similar to TSE but TSE-SSFP uses gradient moment nulling, whereas TSE uses gradient crushing. TSE-SSFP produced T2-weighted images with minimal T1 weighting. TSE-SSFP and TSE had similar SNR (155.9 +/- 6.0 vs 160.9 +/- 7.0; P = NS) for acute myocardial infarction (MI) and twice the SNR of T2-prepared SSFP (73.1 +/- 3.4, P < 0.001). TSE-SSFP and TSE had approximately double the CNR of T2-prepared SSFP for differentiating acute MI from normal myocardium. Imperfect blood suppression, present in all animals on some TSE images, was a problem eliminated by TSE-SSFP and T2-prepared SSFP.
منابع مشابه
T2-prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo.
T2-weighted MRI of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI, and assessing the area at risk of infarction. Conventional T2-weighted imaging of edema uses a turbo spin-echo (TSE) readout with dark-blood preparation. Clinical applications of dark-blood TSE methods can be limited by artifacts such as posterior wall signal loss due to throug...
متن کاملT2 mapping vs T2 weighted imaging in the detection of myocardial oedema
Background The “gold standard” CMR sequence for assessing the myocardial oedema or area at risk following an acute coronary syndrome is controversial. T2 Short Tau Inversion Recovery (T2-STIR) is in widespread clinical use but can lack robustness. Steady state free precession oedema imaging (SSFP/ ACUT2E) has emerging data to support it as a more reproducible method for area at risk (AAR) asses...
متن کاملT2-prepared SSFP Improves Diagnostic Confidence in Edema Imaging in Acute Myocardial Infarction Compared with Turbo-SpinEcho
Introduction T2-weighted MR imaging of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI and for assessing the area-at-risk of infarction. Standard T2-weighted imaging of edema uses a turbo-SpinEcho (TSE) readout with dark-blood preparation. Dark-blood TSE methods are subject to artifacts such as posterior wall signal loss due to cardiac motion a...
متن کاملSSFP cine images early post-gadolinium improve detection of myocardial oedema in acute myocardial infarction compared to T2-weighted dark blood turbo spin echo images
Background Demonstration of myocardial oedema following MI allows differentiation of acute and chronic MI, and assessment of the area at risk of infarction. T2-weighted dark blood TSE imaging for oedema is technically demanding and prone to artefacts. Our protocol for patients with acute MI include standard oedema imaging sequences and more recently T2 prepared single shot SSFP sequences, follo...
متن کاملEarly gadolinium enhancement for the detection of myocardial oedema (EGE vs T2-STIR vs ACUT2E): a new method to assess the area at risk?
Background The “gold standard” CMR sequence for assessing the myocardial oedema or area at risk following an acute coronary syndrome is controversial. Short Tau Inversion Recovery (T2-STIR) is in widespread clinical use. Steady state free precession oedema imaging (SSFP/ ACUT2E) has emerging data to support it as a more reproducible method for area at risk (AAR) assessment. More recently, early...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 59 2 شماره
صفحات -
تاریخ انتشار 2008