A simple X-ray emitter.

نویسندگان

  • Hiroaki Murakami
  • Ryoichi Ono
  • Atsuhiko Hirai
  • Yoshinori Hosokawa
  • Jun Kawai
چکیده

A compact X-ray emission instrument is made, and the X-ray spectra are measured by changing the applied electric potential. Strong soft X-rays are observed when evacuating roughly and applying a high voltage to an insulator settled in this device. The X-ray intensity is higher as the applied voltage is increased. A light-emitting phenomenon is observed when this device emits X-rays. The present X-ray emitter is made of a small cylinder with a radius of 20 mm and a height of 50 mm. This X-ray generator has a potential to be used as an X-ray source in an X-ray fluorescence spectrometer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carbon Nanotube Electron Emitter for X-ray Imaging

The carbon nanotube field emitter array was grown on silicon substrate through a resist-assisted patterning (RAP) process. The shape of the carbon nanotube array is elliptical with 2.0 × 0.5 mm for an isotropic focal spot size at anode target. The field emission properties with triode electrodes show a gate turn-on field of 3 V/μm at an anode emission current of 0.1 mA. The author demonstrated ...

متن کامل

X-ray absorption spectral analysis with a 9 V battery X-ray generator.

X-ray absorption spectral (XAS) analysis is performed with a combination of a 9 V dry electric battery X-ray generator and a portable Si PIN X-ray detector. The calcium K edge (4.0 keV) in paper is measured with a grazing incidence geometry, which suppressed the artifact due to the Kalpha X-ray fluorescence peak at 3.5 keV. The 9 V dry battery X-ray emitter is useful for portable XAS measurements.

متن کامل

X-ray and UV observations with XMM-Newton

We present an XMM-Newton observation of NGC 7469, including studies of the X-ray and UV variability, 0.2−10 keV spectral continuum, Fe Kα emission line and the first-ever high-resolution X-ray spectrum of the soft X-ray warm absorber. We compare the properties of this X-ray warm absorber with the UV warm absorber as seen in a FUSE observation one year previously. The 0.2−10 keV spectral continu...

متن کامل

XMM - Newton observations of the massive colliding wind binary and non - thermal radio emitter Cyg OB 2 # 8 A ( O 6 If + O 5 . 5 III ( f ) ) ?

We report on the results of four XMM-Newton observations separated by about ten days from each other of Cyg OB2 #8A (O6If + O5.5III(f)). This massive colliding wind binary is a very bright X-ray emitter – one of the first X-ray emitting O-stars discovered by the Einstein satellite –as well as a confirmed non-thermal radio emitter whose binarity was discovered quite recently. The X-ray spectrum ...

متن کامل

Chandra Imaging of the Gamma-ray Source Gev J1809-2327

We report on Chandra imaging observations of the Galactic Unidentified γ-ray source GEV J1809-2327, comparing the X-ray images with new VLA 1.46 GHz and 4.86 GHz maps. The X-ray images reveal a point source connected to a non-thermal X-ray/radio nebula, supporting a pulsar/wind model for the γ-ray emitter. We also detect numerous X-ray sources from the young stellar association in the adjacent ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 7  شماره 

صفحات  -

تاریخ انتشار 2005