Motion Correction of EPI sequences using their intrinsic high-frequency content

نویسندگان

  • Maximilian Haeberlin
  • Alexander Aranovitch
  • Lars Kasper
  • Christoph Barmet
  • Klaas Paul Pruessmann
چکیده

Fig. 3 Top: Head translation (left) and rotation (center) for the experiment with EPI based motion correction. Corresponding image reconstruction (right) shows successful slice tracking using the proposed method. Bottom: Head translation (left) and rotation (center) in the uncorrected case. The corresponding image reconstructions (right) show three different slices due to unaccounted head motion. Fig. 2 Precision of the field probe localization with the proposed method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Motion correction for functional MRI with three‐dimensional hybrid radial‐Cartesian EPI

PURPOSE Subject motion is a major source of image degradation for functional MRI (fMRI), especially when using multishot sequences like three-dimensional (3D EPI). We present a hybrid radial-Cartesian 3D EPI trajectory enabling motion correction in k-space for functional MRI. METHODS The EPI "blades" of the 3D hybrid radial-Cartesian EPI sequence, called TURBINE, are rotated about the phase-e...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

MR-based and Optical Prospective Motion Correction for High Resolution DWI with RS-EPI

Introduction: Recently, multiple approaches have been proposed to perform motion correction for diffusion imaging using optical tracking with cameras [1,2] or using MR-based methods which perform real-time registration between volumes [3-5]. In this study, we demonstrate the application of and compare both optical and MR-based motion correction to high-resolution diffusion-weighted imaging usin...

متن کامل

Influences of temporal evolution of ground motion frequency content on developed dynamic ratcheting in SDOF systems

Dynamic Ratcheting (DR) is a nonlinear dynamic phenomenon occurring in hysteretic damping systems. It means the structural plastic deformation increases asymmetrically in successive cycles under an earthquake excitation. Although it is generally recognized that DR is closely related to the frequency contents of an earthquake excitation applied to thestructure, no targeted analysis has bee...

متن کامل

Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.

Diffusion-weighted imaging (DWI) obtained with interleaved echo-planar imaging (EPI) pulse sequence has great potential of characterizing brain tissue properties at high spatial-resolution. However, interleaved EPI based DWI data may be corrupted by various types of aliasing artifacts. First, inconsistencies in k-space data obtained with opposite readout gradient polarities result in Nyquist ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013