S2 connector versus suture: distal coronary anastomosis remodeling, patency, and function in the pig.

نویسندگان

  • Willem J L Suyker
  • John P Matonick
  • Paul T W Suyker
  • Aart Brutel de la Rivière
  • Marc P Buijsrogge
  • Ricardo P J Budde
  • Cees W J Verlaan
  • Gerard Pasterkamp
  • Paul F Gründeman
  • Cornelius Borst
چکیده

BACKGROUND Anastomotic connectors could be the key to less invasive bypass surgery, including endoscopic procedures, but equivalence to conventional suturing needs to be established. A novel distal coronary connector was tested pre-clinically for safety and efficacy in comparison to conventional suturing. METHODS AND RESULTS Left internal thoracic to left anterior descending coronary artery bypasses were constructed off-pump in 35 pigs (73+/-8 kg). An intraluminal metal connector (S2AS) was used in 21 and conventional suturing in 14 animals. S2AS anastomosis construction was easier achieved in one-fourth of the conventional construction time (3.7+/-0.7 versus 16.5+/-2.6 minutes; P<0.001). Acute patency tended to be better (P=0.15). All anastomoses were evaluated intraoperatively, and subgroups at 90 and at 180 days. Patency was 100%. An effective remodeling response was observed in all groups, resulting in unobstructed anastomoses with excellent hemodynamic performance (fractional flow reserve > or = 0.93 at 180 days). At 6 months, the noncompliant connector was covered with stabilized neointima that was thinner than found on the suture line (0.10+/-0.04 versus 0.31+/-0.13 mm; P=0.01). The connector induced less lumen loss (-0.6+/-6.5 versus 21.6+/-19%; P=0.03). The initial side-to-side configuration had remodeled to an end-to-side shape as intended. CONCLUSIONS In the porcine model, the connector rapidly and consistently produced high-quality anastomoses that fully met current standards on patency and function. Unconventional aspects like a noncompliant intraluminal ring and a side-to-side to end-to-side converted configuration did not interfere with favorable anastomosis remodeling. These findings shed a new light on the anatomical prerequisites for anastomosis patency.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal Coronary Anastomosis Remodeling, Patency, and Function in the Pig

Background—Anastomotic connectors could be the key to less invasive bypass surgery, including endoscopic procedures, but equivalence to conventional suturing needs to be established. A novel distal coronary connector was tested pre-clinically for safety and efficacy in comparison to conventional suturing. Methods and Results—Left internal thoracic to left anterior descending coronary artery byp...

متن کامل

Pii: S1010-7940(02)00378-0

Surgical environment is becoming increasingly challenging for the cardiac surgeon since off-pump coronary arteries bypass grafts and minimally invasive approach came up. The suture technique for coronary anastomosis construction is becoming inadequate to meet new surgeons’ demand. Therefore, there is an increasing need for alternative ways to perform coronary bypasses. This article reviews the ...

متن کامل

Internal thoracic artery to left anterior descending anastomosis performed on the beating heart by endoscopic robot assistance using a new distal connector.

BACKGROUND Automated distal connecting devices have been recently introduced to facilitate coronary anastomosis. This could have a large impact on the capacity of robotic systems to perform completely endoscopic off-pump bypass, where the quality of anastomosis and the prolonged operative time for the performance of the anastomosis have until now been cause for concern. Our group tried to deter...

متن کامل

Evaluation of a novel 2 mm internal diameter stainless steel saphenous vein to coronary artery connector: laboratory studies of on-pump and off-pump revascularization.

OBJECTIVE A second generation, 'easy-load', 2 mm internal diameter (ID), stainless steel, distal anastomotic device has been developed, and design improvements facilitate rapid connector loading with minimal magnification. The reduced size should allow application to most distal coronary vessels currently grafted. This technology may be useful in off-pump and minimally invasive surgical approac...

متن کامل

Simple Anastomotic Techniques for Coronary Artery Bypass Surgery in Patients with Small Coronary Arteries or a Marked Size Discrepancy Between the Coronary Artery and Graft

Different suture techniques have been used for anastomosis in coronary artery bypass graft surgery. Bypass surgery may be difficult for patients who have small coronary arteries or marked size discrepancies between target coronary arteries and grafts. For proximal and distal anastomoses, three continuous stitches are first placed in the heel and toe of the small coronary arteries; for sequentia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 114 1 Suppl  شماره 

صفحات  -

تاریخ انتشار 2006