Proximal Femoral Shortening after Operation with Compression Hip Screws for Intertrochanteric Fracture in Patients under the Age of 60 Years

نویسندگان

  • Won-Kee Choi
  • Myung-Rae Cho
  • Dong-Young Kim
چکیده

PURPOSE We aimed to quantify proximal femoral shortening after operation with compression hip screws for intertrochanteric fracture in patients under the age of 60 years. MATERIALS AND METHODS We followed 37 consecutive patients with intertrochanteric fractures treated with compression hip screws from March 2005 to February 2014. We designated the aspect of the fracture, a defect of the postero-medial wall, a defect of the lateral wall, and the degree of reduction as four potentially important factors we assumed would strongly affect proximal femoral shortening. We quantified proximal femoral shortening and compared the effects of above factors. We divided femoral shortening into two plane vectors; femoral offset in the horizontal plane and leg length discrepancy in the vertical plane. We measured shortening separately during two periods: during operation and after weight bearing (called dynamic compression). RESULTS After bone union, the average femoral offset shortening was 5.45 mm. Patient groups with anatomic reduction and intact postero-medial wall showed lower femoral offset shortening than the respective opposite groups. As to functional score using modified Harris hip score, low femoral offset shortening group showed more 2.35 scores than high groups. None of the factors significantly affected leg length shortening. CONCLUSION We found that a stable medial buttress is involved in lower femoral offset shortening. Thus, surgeons need to attempt to recover the defect of the medial wall and to reduce anatomically when operating intertrochanteric fractures with compression hip screws.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)

  Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...

متن کامل

Unstable Intertrochanteric Fracture Fixation – Is Proximal Femoral Locked Compression Plate Better Than Dynamic Hip Screw Naiyer aSif1, SOhail ahmad2, OwaiS ahmad QureShi3, latif Zafar JilaNi4, taJdar hameSh5,

Background: Intertrochanteric fractures are one of the most common fractures encountered in our practice. Most of them need operative intervention and union is achieved. As per the literature dynamic hip screw (DHS) is the gold standard for the treatment of these fractures, however problem arises with maintenance of neck shaft angle and proper reduction in unstable intertrochanteric fractures. ...

متن کامل

Clinical and Functional Outcomes of Treatment for Type A1 Intertrochanteric Femoral Fracture in Elderly Patients: Comparison of Dynamic Hip Screw and Proximal Femoral Nail Antirotation

PURPOSE We aimed to evaluate and compare the clinical and functional outcomes of dynamic hip screw (DHS) and proximal femoral nail antirotation (PFNA) treatment of AO type 1 intertrochanteric fractures in elderly patients. MATERIALS AND METHODS We retrospectively reviewed 194 consecutive patients with type A1 intertrochanteric femoral fractures who were treated with DHS (n=113) or PFNA (n=81)...

متن کامل

Lower Bone Mineral Density is Associated with Intertrochanteric Hip Fracture

Background: A better understanding of how bone mineral density and vitamin D levels are associated with femoralneck and intertrochanteric hip fractures may help inform healthcare providers. We asked: 1) In patients age ≥ 55 years,is there a difference in quantitative ultrasound of the heel (QUS) t-score between patients with fractures of the femoralneck and those with fractures of the intertroc...

متن کامل

Femoral shortening in intertrochanteric fractures. A comparison between the Medoff sliding plate and the compression hip screw.

We compared 54 patients treated by a Medoff sliding plate (MSP) with 60 stabilised by a compression hip screw (CHS) in a prospective, randomised study of the management of intertrochanteric femoral fractures. Four months after the operation femoral shortening was determined from radiographs of both femora. In unstable fractures the mean femoral shortening was 15 mm with the MSP and 11 mm with t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 27  شماره 

صفحات  -

تاریخ انتشار 2015