Diagnosis of urinary bladder diseases in dogs by using two-dimensional and three-dimensional ultrasonography.
نویسندگان
چکیده
AIM The objective of this study was to obtain and compare two-dimensional (2D) and three-dimensional (3D) ultrasonographic images of the urinary bladder in different disease conditions. MATERIALS AND METHODS The present study was conducting on total 10clinical cases of the urinary bladder in dogs. The ultrasound (US) machine used for this study was 3D US machine (Nemio-XG: Toshiba, Japan) having a four-dimensional volumetric probe. RESULTS In the present study, the inflamed thickened wall was clearly visible with the distinction of different layers of the urinary bladder wall in some of the cases of cystitis using 2D ultrasonography. In 3D sonogram, the urinary bladder was visualized as a large anechoic structure with no distinction of different layers of the bladder wall. The cystoliths were clearly visible as hyperechoic structures with distal acoustic shadow in 2D sonogram and appeared as a bright echogenic area in 3D sonogram. In case of urinary bladder neoplasia in 2D ultrasonogram, the bladder lumen was found to be occluded with a large growth imaged as focal anechoic areas in the tissue of mixed echogenicity with small hyperechoic dots in this tissue parenchyma. In 3D ultrasonogram, a tissue of mixed echogenicity of pus was also observed. CONCLUSION From the present study it was concluded that 2D and 3D ultrasonography is very helpful for diagnosis of different clinical conditions of the urinary bladder such as cystitis, cystoliths, and urinary bladder neoplasia. The cavity of urinary bladder was more clearly visualized in 3D ultrasonography, but the distinction of different layers of the bladder wall was visualized only in 2D ultrasonography. The distinct shadow of pus and cystoliths were visible in 2D ultrasonogram. The visualization of pus in 3D ultrasonography was done for the first time in present study.
منابع مشابه
Three-dimensional Power Doppler Ultrasonographic Evaluation of Induced Cystitis in Dogs
Objectives: The aim of this study was to investigate if three-dimensional power Doppler (3DPD) ultrasound (US) can detect bacterial cystitis in dogs better than two-dimensional (2D) US. Animals: Six mixed breed dogs Procedures: Ten ml of 0.1% alcoholic solution of salicylic acid was entered into the urinary bladder of six male mixed-breed dogs by catheter. Twenty four hours later, culture sol...
متن کاملThree-dimensional Volumetric Ultrasonography of Enlarged Adrenal Gland in Dog
Objective: Detection and evaluation of adrenal glands are complex problems in conventional ultrasonography in dogs. Using three-dimensional (3D) ultrasonography (US) in adrenal gland volume evaluation can add new potential for further adrenal studies. Design: Descriptive study Animals: a total of 10 mix breed dogs Procedures: The dogs underwent two dimensional (2D) and 3D US of the adrenal g...
متن کاملPossibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs
Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...
متن کاملThree-dimensional color Doppler ultrasonography of the kidney vasculature in normal dogs
Three-dimensional color Doppler ultrasonography is a new technique to evaluate the pattern of blood vessels. This study was performed to assess the feasibility of this method in evaluation of kidney vasculature pattern in dogs. In this paper, visualization of the Renal, Interlobar, Arcuate, and interlobular arteries and veins using 3D color Doppler ultrasonography in dogs is shown and the techn...
متن کاملThree Dimensional Ultrasonography of the Eye and Measurement of Optical Nerve Sheet Diameter in Dog
Objective- To determine the possibility of three-dimensional ultrasonography (3DUS) and measurement of optical nerve sheet by this method. Design- Descriptive study. Animals- 10 mixed normal dogs (5males, 5 females), age 1-1.5 year, and weighting 15±5 kg Procedure- 3D ultrasounds of the eyes were evaluated and the normal optical nerves in 3DUS images were measured using Volouson 730 pro....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Veterinary world
دوره 8 7 شماره
صفحات -
تاریخ انتشار 2015