Normalization of Ventilation Data from 4D-CT to Facilitate Comparison between Datasets Acquired at Different Times

نویسندگان

  • Kujtim Latifi
  • Vladimir Feygelman
  • Eduardo G. Moros
  • Thomas J. Dilling
  • Craig W. Stevens
  • Geoffrey G. Zhang
چکیده

PURPOSE The 4D-CT data used for comparing a patient's ventilation distributions before and after lung radiotherapy are acquired at different times. As a result, an additional variable--the tidal volume (TV)--can alter the results. Therefore, in this paper we propose to normalize the ventilation to the same TV to eliminate that uncertainty. METHODS Absolute ventilation (AV) data were generated for 6 stereotactic body radiation therapy (SBRT) cases before and after treatment, using the direct geometric algorithm and diffeomorphic morphons deformable image registration (DIR). Each pair of AV distributions was converted to TV-normalized, percentile ventilation (PV) and low-dose well-ventilated-normalized ventilation (LDWV) distributions. The ventilation change was calculated in various dose regions based on the treatment plans using the DIR-registered before and after treatment data sets. The ventilation change based on TV-normalized ventilation was compared with the AV as well as the data normalized by PV and LDWV. RESULTS AV change may be misleading when the TV differs before and after treatment, which was found to be up to 6.7%. All three normalization methods produced a similar trend in ventilation change: the higher the dose to a region of lung, the greater the degradation in ventilation. In low dose regions (<5 Gy), ventilation appears relatively improved after treatment due to the relative nature of the normalized ventilation. However, the LDWV may not be reliable when the ventilation in the low-dose regions varies. PV exhibited a similar ventilation change trend compared to the TV-normalized in all cases. However, by definition, the ventilation distribution in the PV is significantly different from the original distribution. CONCLUSION Normalizing ventilation distributions by the TV is a simple and reliable method for evaluation of ventilation changes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Four-dimensional (4D) Computed Tomography (CT) Pulmonary Ventilation Imaging by Comparison with Single Photon Emission Computed Tomography (SPECT) Scans for a Lung Cancer Patient

The goal of this study was to present a method for physiologic validation and show results for a comparison of the 4D-CT ventilation and SPECT ventilation or perfusion. A 4D-CT and a SPECT ventilation/perfusion (V/Q) (VSPECT and QSPECT) scans were acquired for a lung cancer patient. Two 4D-CT ventilation images were created using two metrics: Hounsfield unit (HU)-change (V4D-CT) and Jacobian de...

متن کامل

Evaluation of the ΔV 4D CT ventilation calculation method using in vivo xenon CT ventilation data and comparison to other methods

Ventilation distribution calculation using 4D CT has shown promising potential in several clinical applications. This study evaluated the direct geometric ventilation calculation method, namely the ΔV method, with xenon-enhanced CT (XeCT) ventilation data from four sheep, and compared it with two other published meth-ods, the Jacobian and the Hounsfield unit (HU) methods. Spearman correlation c...

متن کامل

A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...

متن کامل

Effects of quantum noise in 4D-CT on deformable image registration and derived ventilation data.

Quantum noise is common in CT images and is a persistent problem in accurate ventilation imaging using 4D-CT and deformable image registration (DIR). This study focuses on the effects of noise in 4D-CT on DIR and thereby derived ventilation data. A total of six sets of 4D-CT data with landmarks delineated in different phases, called point-validated pixel-based breathing thorax models (POPI), we...

متن کامل

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013