Towards Intra-operative 3D Nuclear Imaging: Reconstruction of 3D Radioactive Distributions Using Tracked Gamma Probes

نویسندگان

  • Thomas Wendler
  • Alexander Hartl
  • Tobias Lasser
  • Jörg Traub
  • Farhad Daghighian
  • Sibylle Ilse Ziegler
  • Nassir Navab
چکیده

Nuclear medicine imaging modalities assist commonly in surgical guidance given their functional nature. However, when used in the operating room they present limitations. Pre-operative tomographic 3D imaging can only serve as a vague guidance intra-operatively, due to movement, deformation and changes in anatomy since the time of imaging, while standard intra-operative nuclear measurements are limited to 1D or (in some cases) 2D images with no depth information. To resolve this problem we propose the synchronized acquisition of position, orientation and readings of gamma probes intra-operatively to reconstruct a 3D activity volume. In contrast to conventional emission tomography, here, in a first proof-of-concept, the reconstruction succeeds without requiring symmetry in the positions and angles of acquisition, which allows greater flexibility. We present our results in phantom experiments for sentinel node lymph node localization. The results indicate that 3D intra-operative nuclear images can be generated in such a setup up to an accuracy equivalent to conventional SPECT systems. This technology has the potential to advance standard procedures towards intra-operative 3D nuclear imaging and offers a novel approach for robust and precise localization of functional information to facilitate less invasive, image-guided surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Manipulation 3D Imaging System by using Photodiode Grid

Introduction: Radiation imaging is one of the applicable methods in diagnostic medicine and nondestructive testing for industrial applications. In nondestructive 3D imaging, in addition to the radiation source, there is a requirement for a suitable detection system, data acquisition system, mechanical sections for moving objects, reconstruction algorithm and finally a computer for processing an...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

First Flexible Robotic Intra-operative Nuclear Imaging for Image-Guided Surgery

First flexible robotic intra-operative nuclear imaging for image-guided surgery José Gardiazabal tum.de Tobias Reichl tum.de Aslı Okur tum.de Tobias Lasser tum.de Nassir Navab tum.de Functional imaging systems for intra-operative use, like freehand SPECT, have been successfully demonstrated in the past, with remarkable results. These results, even though very positive in some cases, tend to suf...

متن کامل

Computational modeling of detection physics for 3D intraoperative imaging with navigated nuclear probes

Today we can look at and into patients with many different modalities. We are able to produce 3D images of the patient’s body with incredible accuracy and we can even image functions within the body. These imaging techniques are extremely helpful for diagnostics. However in intra-operative settings most of these imaging techniques suffer from severe drawbacks. They are either not flexible enoug...

متن کامل

Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom

Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 10 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2007