Improved potentiometric response of all-solid-state Pb(2+)-selective electrode.

نویسندگان

  • Shunyang Yu
  • Qun Yuan
  • Fuhai Li
  • Yongming Liu
چکیده

Zero-current ion-flux has a great influence on the characteristics of the ion-selective electrodes. In this work the improvement of analytical performance of all-solid-state Pb(2+)-selective membrane electrodes was demonstrated by adjusting the transmembrane ion flux. The study is focused on the relationship between the conditioning solution and the linear working range of the obtained electrodes for different sample matrixes. Results show that the electrode with appropriate conditioning keeps good reproducibility within linear working range. The utility of the electrode has been tested by successfully determining Pb(2+) concentration in real water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

متن کامل

Nitrate-selective membrane electrode based on bis(2-hydroxyanil)acetylacetone lead(II) neutral carrier.

A nitrate-selective electrode based on a recently synthesized bis(2-hydroxyanil)acetylacetone lead(II) complex [(haacac)Pb] has been developed. Among different compositions studied, a membrane containing 30.7% poly(vinyl chloride) (PVC), 61.3% dibutyl phthalate (DBP) as a plasticizer, 3% methyltrioctylammonium chloride (MTOAC) as a cationic additive and 5% ionophore (all w/w) exhibited the best...

متن کامل

Green Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes

Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...

متن کامل

Selective Potentiometric Sensor for Isoniazid Ultra-Trace Determination Based on Fe3O4 Nanoparticles Modified Carbon Paste Electrode (Fe3O4/CPE)

   Significant effects of magnetic iron oxide (Fe3O4) nanoparticles on the potentiometric behavior of carbon paste electrode for bio determination of Isoniazid aromatic drug (INH) were studied. The electrochemical performance of modified Fe3O4/CPE was investigated. The constructed Fe3O4/CPE showed high precision, sensitivity ...

متن کامل

Preparation of Low Cost Solid State Silver Sulfide Based Bromide Selective Electrodes

Preparation and performance of a cost effective silver sulfide based bromide selective membrane is described. A solid contact between membrane and body of the electrode was examined as an ion-selective electrode by determining S 2and Br ions by direct potentiometry. A linear response to bromide ion from 2 x 10 -5 to 10 -1 M with a slope of 57.3 mV per decade [Br ] is observed. The membrane has ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 101  شماره 

صفحات  -

تاریخ انتشار 2012