A 300 GHz collective scattering diagnostic for low temperature plasmas.

نویسندگان

  • Robert A Hardin
  • Earl E Scime
  • John Heard
چکیده

A compact and portable 300 GHz collective scattering diagnostic employing a homodyne detection scheme has been constructed and installed on the hot helicon experiment (HELIX). Verification of the homodyne detection scheme was accomplished with a rotating grooved aluminum wheel to Doppler shift the interaction beam. The HELIX chamber geometry and collection optics allow measurement of scattering angles ranging from 60 degrees to 90 degrees. Artificially driven ion-acoustic waves are also being investigated as a proof-of-principle test for the diagnostic system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thomson scattering from near–solid density plasmas using soft x–ray free electron lasers

We propose a collective Thomson scattering experiment at the VUV free electron laser facility at DESY (FLASH) which aims to diagnose warm dense matter at near–solid density. The plasma region of interest marks the transition from an ideal plasma to a correlated and degenerate many–particle system and is of current interest, e.g. in ICF experiments or laboratory astrophysics. Plasma diagnostic o...

متن کامل

Light-scattering study of a supercooled epoxy resin.

The dynamics of the fragile glass-forming liquid diglycidyl ether of bisphenol-A was studied by depolarized Rayleigh-Brillouin light-scattering and photon correlation spectroscopy above the glass transition, in the temperature range from 261 to 473 K and in the frequency range from 1 Hz to 300 GHz. The structural (alpha-) relaxation process was revealed and no signature of the secondary relaxat...

متن کامل

Instability-enhanced collisional effects and Langmuir's paradox.

Anomalously fast equilibration of the electron distribution function to a Maxwellian in gas-discharge plasmas with low temperature and pressure, i.e., Langmuir's paradox, may be explained by electron scattering via an instability-enhanced collective response and hence fluctuations arising from convective ion-acoustic instabilities near the discharge boundaries.

متن کامل

PFC / JA - 93 - 25 ITER Millimeter - Wave CTS Diagnostic Option

Localized alpha-particle velocity distribution and density, ion temperature, DT fuel ratio, and internal magnetic field pitch angle can all be potentially diagnosed by a collective Thomson scattering system. Relativistic electron cyclotron calculations and TORAY ray tracing for 6 tesla ITER parameters indicate that 90 GHz is an optimum frequency for this diagnostic. With 400 kW at the plasma an...

متن کامل

A polarization-based Thomson scattering technique for burning plasmas

The traditional Thomson scattering diagnostic is based on measurement of the wavelength spectrum of scattered light, where electron temperature measurements are inferred from thermal broadening of the spectrum. At sufficiently high temperatures, especially those predicted for ITER and other burning plasmas, relativistic effects cause a change in the degree of polarization (P) of the scattered l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 79 10  شماره 

صفحات  -

تاریخ انتشار 2008