Frequency domain near-infrared multiwavelength imager design using high-speed, direct analog-to-digital conversion.

نویسندگان

  • Bernhard B Zimmermann
  • Qianqian Fang
  • David A Boas
  • Stefan A Carp
چکیده

Frequency domain near-infrared spectroscopy (FD-NIRS) has proven to be a reliable method for quantification of tissue absolute optical properties. We present a full-sampling direct analog-to-digital conversion FD-NIR imager. While we developed this instrument with a focus on high-speed optical breast tomographic imaging, the proposed design is suitable for a wide-range of biophotonic applications where fast, accurate quantification of absolute optical properties is needed. Simultaneous dual wavelength operation at 685 and 830 nm is achieved by concurrent 67.5 and 75 MHz frequency modulation of each laser source, respectively, followed by digitization using a high-speed (180 MS∕s) 16-bit A/D converter and hybrid FPGA-assisted demodulation. The instrument supports 25 source locations and features 20 concurrently operating detectors. The noise floor of the instrument was measured at <1.4 pW∕ p Hz, and a dynamic range of 115+ dB, corresponding to nearly six orders of magnitude, has been demonstrated. Titration experiments consisting of 200 different absorption and scattering values were conducted to demonstrate accurate optical property quantification over the entire range of physiologically expected values. © 2016 Society of Photo-Optical Instrumentation Engineers (SPIE) [DOI: 10.1117/1.JBO.21.1.016010]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medical near-infrared imaging

The use of near-infrared light in functional medical imaging has gained increasing interest during recent years. Techniques using near-infrared light for imaging can be used to study, e.g., hemodynamic responses on the cortex. Brain activation measurements can be performed using, e.g., MEG or fMRI, which, however, require heavy instrumentation. In medical near-infrared imaging, the instrumentat...

متن کامل

An interline CCD imaging array with on-chip A/D conversion

In this paper we describe an interline CCD imaging array which features high-speed, on-chip, parallel A/D conversion. In addition, we present test results from fabricated devices. The imaging chip was fabricated through MOSIS in a double-poly 2:0m CCD/CMOS technology on a chip with total area 2:25mm 2:22mm. The chip is composed of two components, namely, a 28 39 pixel, interline imaging array a...

متن کامل

A multimodal breast cancer imaging system using coregistered dynamic diffuse optical tomography and digital breast tomosynthesis

Diffuse optical tomography (DOT) is an emerging noninvasive functional imaging method for breast cancer diagnosis and neoadjuvant chemotherapy monitoring. In particular, the multimodal approach of combining DOT with x-ray digital breast tomosynthesis (DBT) is especially synergistic as DBT prior information can be used to enhance the DOT reconstruction. DOT, in turn, provides a functional inform...

متن کامل

A Digital-Front-End Enhanced Multi-Mode/Multi-Standard Wireless Receiver

This paper presents a multi-mode receiver concept for different transmission standards like UMTS and IS95. Due to the use of a Digital-Front-End (DFE) the requirements for the analog part of the well known direct conversion receiver (DCR) architecture decrease because channelization and fine frequency tuning are shifted from the analog into the digital domain. The adaptation of the channelizati...

متن کامل

24-Bit 5.0 GHz Direct Digital Synthesizer RFIC With Direct Digital Modulations in 0.13 μ m SiGe BiCMOS Technology

This paper presents a 24-bit 5.0 GHz ultrahigh-speed direct digital synthesizer (DDS) with direct digital modulation capabilities used in a pulse compression radar. This design represents the first DDS RFIC in over-GHz output frequency range with direct digital modulation capabilities. It adopts a ROM-less architecture and has the capabilities for direct digital frequency and phase modulation w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2016