Performance evaluation of multi-stage open-loop impedance pump

نویسندگان

  • V. C. C. Lee
  • Y. A. Abakr
  • K. C. Woo
چکیده

Background: Impedance pump is a simple valveless pumping mechanism, which transports fluid through the mismatch of impedance in the system. Mismatch in impedance occurs when an asymmetrical periodic excitation is exerted on the elastic tube. Periodic asymmetrical excitation will then produce a unidirectional flow. Considering a multi-stage system with a single and constant power source, it is well expected that there would be pumping limitation to which the enhancement can reach. Methods: A multi-stage open-loop impedance pump is developed in the current work. The current work experimentally analyzes and evaluates the pumping performance of a multi-stage open-loop impedance pump, with emphasis on the flow rates induced and pumping limitation. Analyses of flow rates, pressure head and excitation frequencies are performed in its non-dimensional form. Results: Taking a single-stage system as benchmark, enhancement of 35 and 33.3% is shown in the flow rate and pressure head respectively for a two-stage system. Enhancement of 110 and 60% is shown in flow rate and pressure head of a three-stage system in comparison to the single-stage system. For four-stage system, however, only 27 and 46.7% increments are demonstrated in the flow rate and pressure head, respectively. Conclusions: The implementation of multi-stage system with single constant power input is demonstrated to be limited only to the three-stage system where the declined pumping performance is exhibited in a four-stage system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigation of Open Loop Multi-stage Impedance Pumping System

Impedance pump is a simple valveless pumping mechanism, where an elastic tube is joined to a more rigid one; a periodic asymmetrical pinching on the elastic tube will produce a unidirectional flow. This pumping concept offers a low energy, low noise alternative at both micro and macro scales. This paper describes an experimental investigation of the performance of a two-stage, open loop impedan...

متن کامل

An Experimental Investigation into the Effects of High Viscosity and Foamy Oil Rheology on a Centrifugal Pump Performance

This paper presents the effect of high viscosity oil and two-phase foamy-oil flow on the performance of a single stage centrifugal pump. As a part of this, the applicability of a pipe viscometer to determine the foamy oil viscosity is investigated. Unlike previous studies, a sealed fluid tank is used in a closed flow loop to allow conditioning the two-phase mixture to create foamy-oil. Furtherm...

متن کامل

Design of Compact Multi-Channel Diplexer Using Defected Microstrip Structure

In this paper, two compact quad-channel and six-channel diplexer are designed and fabricated using defected microstrip structure (DMS). This structure is designed for the desired frequency based on the literature reviews. The proposed configuration is composed of a conventional T-junction divider with two pairs of open bended stubs and dual/tri-band filters. In designing dual band filters, a lo...

متن کامل

Determining Performance Evaluation Indicators of Military Nurses in Iran: A Multi-Stage Study

Background and Aim: Improving the performance appraisal system in the armed forces health care system is one of the challenges for managers in this field. Therefore, this study aimed to develop performance evaluation indicators of nurses working in military medical centers in Iran. Methods: The present study is an applied and multi-stage research that was conducted in three general phases durin...

متن کامل

Performance of the Load-in-the-Loop Single Op-Amp Voltage Controlled Current Source from the Op-Amp Parameters

In recent years, Electrical Bioimpedance (EBI) methods have gained importance. These methods are often based on obtaining impedance spectrum in the range of β-dispersion, i.e. from a few kHz up to some MHz. To measure EBI a constant current is often injected and the voltage across the tissue under study is recorded. Due to the performance of the current source influences the performance of the ...